arrow
Return

Phase-shift fiber-loop ring-down spectroscopy

delete2004-10-12
delete72
PRE
AI
Z
Zhaoguo Tong
A
Alexander Wright
T
Theresa M. McCormick
R
Runkai Li
R
Richard D. Oleschuk
H
Hans‐Peter Loock
DOI:10.1021/ac0491253delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Fiber-loop ring-down spectroscopy (FLRDS) is a recently developed absorption spectroscopic technique suitable for very small liquid samples. It is based on measurements of the optical decay constant of laser intensity in a loop made of optical waveguide material. This decay constant changes as small liquid samples containing absorbing species are introduced into the loop. In this report, it is demonstrated that one can also obtain the optical decay constant using a continuous wave laser beam that is intensity modulated and then coupled into an optical fiber loop. The inherent exponential decay in the fiber loop introduces a phase shift of the light emitted from the loop with respect to the pumping beam. By measuring this phase shift, one can readily determine the concentration of the analyte introduced between the two fiber ends and a model is established to describe the relationship. It is demonstrated that this technique, dubbed phase-shift fiber-loop ring-down spectroscopy (PS-FLRDS), is well suited as an absorption detector for any flow system in which the optical absorption path is limited by the instrument architecture. By measuring the phase angle as a function of concentration of 1,1'-diethyl-4,4'-dicarbocyanine iodide in dimethyl sulfoxide, the detection limit was determined as similar to6 muM for a 30-40-mum absorption path. A temporal resolution of similar to100 ms was demonstrated by a rapid displacement of the solutions between the two fiber ends. Proof-of-principle use of the PS-FLRDS detection in capillary flow systems using a commercial four-way microcross established that the alignment of the fiber and the capillary can be made simple and effective, while retaining both a low detection limit and a fast response.
Keywords:
CAVITY RING
OVERTONE ABSORPTIONS
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Analytical Chemistry cover
Analytical Chemistry
IF:
6.7
Papers:
4.7W
Citations:
15.9W

Organization

No organization information available
Cited Papers

Cited Papers

Constraints on Transient Viscoelastic Rheology of the Asthenosphere From Seasonal Deformation
err2018-03-15
err0
errOAAI
errKristel Chanard; Luce Fleitout; Eric Calais; Sylvain Barbot; Jean‐Philippe Avouac
errShare
errSave
errShare
errSave
Exact dynamical decay rate for the almost Mathieu operator
err2020-01-01
err0
errOAAI
errSvetlana Jitomirskaya; Helge Krüger; Wencai Liu
errShare
errSave
A Cryptosporidiosis Outbreak in a Filtered‐Water Supply
err1993-06-01
err0
PREAI
errDave Leland; Jeremy McAnulty; William Keene; Gary Stevens
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Singular solutions in viscoplasticity under plane strain conditions
err2013-04-12
err0
PREAI
errSergei Alexandrov; Yusof Mustafa
errShare
errSave
no more