arrow
Return

Population-based Bayesian regularization for microstructural diffusion MRI with NODDIDA

delete2019-05-26
delete4
delete
OA
AI
M
Meghdoot Mozumder
J
José M. Pozo
S
Santiago Coelho
A
Alejandro F. Frangi *
DOI:10.1002/mrm.27831delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: Information on the brain microstructure can be probed by Diffusion Magnetic Resonance Imaging (dMRI). Neurite Orientation Dispersion and Density Imaging with Diffusivities Assessment (NODDIDA) is one of the simplest microstructural model proposed. However, the estimation of the NODDIDA parameters from clinically plausible dMRI acquisition is ill-posed, and different parameter sets can describe the same measurements equally well. A few approaches to resolve this problem focused on developing better optimization strategies for this non-convex optimization. However, this fundamentally does not resolve ill-posedness. This article introduces a Bayesian estimation framework, which is regularized through knowledge from an extensive dMRI measurement set on a population of healthy adults (henceforth population-based prior). Methods: We reformulate the problem as a Bayesian maximum a posteriori estimation, which includes as a special case previous approach using non-informative uniform priors. A population-based prior is estimated from 35 subjects of the MGH Adult Diffusion data (Human Connectome Project), acquired with an extensive acquisition protocol including high b-values. The accuracy and robustness of different approaches with and without the population-based prior is tested on subsets of the MGH dataset, and an independent dataset from a clinically comparable scanner, with only clinically plausible dMRI measurements. Results: The population-based prior produced substantially more accurate and robust parameter estimates, compared to the conventional uniform priors, for clinically feasible protocols, without introducing any evident bias. Conclusions: The use of the proposed Bayesian population-based prior can lead to clinically feasible and robust estimation of NODDIDA parameters without changing the acquisition protocol.
Keywords:
biophysical tissue models
diffusion MRI
microstructure imaging
modeling
parameter estimation
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

U
University of Sheffield
Scholars:
3.0W
Papers: 2.9W
Citations: 3.9W
U
university of leeds
Scholars:
3.6W
Papers: 3.3W
Citations: 45
Cited Papers

Cited Papers

Analysis of the Effects of Noise, DWI Sampling, and Value of Assumed Parameters in Diffusion MRI Models
err2017-01-16
err63
errOAAI
errHutchinson, Elizabeth B.; Avram, Alexandru V.; Irfanoglu, M. Okan; Koay, C. Guan; Barnett, Alan S.; Komlosh, Michal E.; Ozarslan, Evren; Schwerin, Susan C.; Juliano, Sharon L.; Pierpaoli, Carlo
errShare
errSave
On modeling
err2018-03-01
err266
errOAAI
errNovikov, Dmitry S.; Kiselev, Valerij G.; Jespersen, Sune N.
errShare
errSave
Laser-induced crystallization and conformation control of poly(3-hexylthiophene) for improving the performance of organic solar cells
err2017-10-01
err0
PREAI
errLin Feng; Fei Zheng; Peng-Qing Bi; Xiao-Yu Yang; Meng-Si Niu; Fei Wang; Xiao-Tao Hao
errShare
errSave
errShare
errSave
ICICLE: Interpretable Class Incremental Continual Learning
err2023-10-01
err0
errOAAI
errDawid Rymarczyk; Joost van de Weijer; Bartosz Zieliński; Bartłomiej Twardowski
errShare
errSave
Variability in Absolute Apparent Diffusion Coefficient Values across Different Platforms May Be Substantial: A Multivendor, Multi-institutional Comparison Study
errRADIOLOGY
IF15.2
err2008-11-01
err255
PREAI
errSasaki, Makoto; Yamada, Kei; Watanabe, Yoshiyuki; Matsui, Mieko; Ida, Masahiro; Fujiwara, Shunrou; Shibata, Eri
errShare
errSave
researcher View more