Quantifying upright positioning accuracy with optical surface tracking in radiotherapy

delete2026-03-19
delete0
PRE
AI
N
Nomura, Yusuke *
T
Tanaka, Sodai
H
H. Takei
K
Kinji Maeda
T
Takuro Takekoshi
H
Hideki Iwakami
M
Minoru Tajiri
S
Shunsuke Yonai
H
H. Mizuno
T
T. Inaniwa
H
Hitoshi Ishikawa
DOI:10.1002/acm2.70527delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose This study quantified inter- and intra-fractional setup accuracies in the upright posture and compared them among setups with different immobilization methods.Methods Two and four setups were examined for abdominal and head and neck (HN) cancer treatments, respectively. Fifteen asymptomatic volunteers were positioned to a replicated chair of an upright radiotherapy platform with leg immobilization devices, backrest attachments, thermoplastic masks, and vacuum cushions. The 3D positions of the subject body and masks were monitored by calculating 3D point clouds of 26 surface markers from three camera images. The inter-fractional setup errors were calculated by repeating the same setup five times. The intra-fractional displacements were evaluated while the subjects remained in the setups for 20 min. These setup errors and displacements were compared among the setups with different immobilization methods. The intra-fractional displacements were also compared between this study and previous studies in the supine posture.Results Inter-fractional setup errors in the abdominal setups were reduced from 6.6 +/- 3.3 to 3.9 +/- 1.7 mm by using the masks. The HN setup using both the leg immobilization devices and backrest attachments had the setup errors of 2.9 +/- 1.7 mm. This was smaller than the setup errors observed in three other HN setups that did not use either or both of the devices together. Intra-fractional displacements of these abdominal and HN setups with the immobilization devices were 1.9 +/- 1.1 and 1.8 +/- 1.5 mm, respectively, which were smaller than those in the other setups. These displacements were equivalent to those in the previous studies.Conclusions Utilizing the masks increased upright setup accuracy in the abdominal setup. The leg immobilization devices and backrest attachments provided the highest setup accuracy in the upright HN setup. These findings will be useful to expand the applicability of upright radiotherapy for various cancer treatments.
Keywords:
inter-fractional
intra-fractional
setup accuracy
upright radiotherapy

Journal

J
Journal of Applied Clinical Medical Physics
IF:
2.2
Papers:
286
Citations:
6.1K

Organization

N
national institutes for quantum science & technology
Scholars:
3.4K
Papers: 2.7K
Citations: 0