arrow
Return

Reference Database for a Novel Binocular Visual Function Perimeter: A Randomized Clinical Trial

delete2024-11-01
delete0
delete
OA
AI
V
Vincent Michael Patella
N
Nevin W. El-Nimri *
J
John G. Flanagan
M
Mary K Durbin
T
Timothy Bossie
D
Derek Y. Ho
M
Mayra Tafreshi
M
Michael Chaglasian
D
David Kasanoff
S
Satoshi Inoue
S
Sasan Moghimi
T
Takashi Nishida
M
Murray Fingeret
R
Robert N. Weinreb
DOI:10.1016/j.xops.2024.100583delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: To construct a comprehensive reference database (RDB) for a novel binocular automated perimeter. Design: A four-site prospective randomized clinical trial. Subjects and Controls: Three hundred fifty-six healthy subjects without ocular conditions that might affect visual function were categorized into 7 age groups. Methods: Subjects underwent comprehensive ocular examination of both eyes before enrollment. Using the TEMPO/IMOvifa automated perimeter (Topcon Healthcare/CREWT Medical Systems), each subject completed 4 binocular threshold visual field (VF) tests during a single visit: First, practice 24-2 and 10-2 tests were obtained from both eyes. Next, study 24-2 and 10-2 tests were obtained from both eyes. Test order of each sequence was randomized, and the tests were conducted under standard automated perimetry testing conditions: Goldmann stimulus size III, 3183 cd/m2 2 maximum stimulus intensity, and background intensity of 10 cd/m2, 2 , using AIZERapid test strategy. Standard VF reliability indices were assessed. For each subject, 24-2 and 10-2 test results from 1 randomly selected eye were analyzed. Main Outcome Measures: Perimetric threshold sensitivity and reference limits for each test analysis parameter. Results: The ages of the study cohort were widely distributed, with a mean age (standard deviation [SD]) of 52.3 (18.5) years. Sex assignment was 44.0% male and 56.0% female. The majority of subjects self-identified as White (67.4%), followed by Black or African American (13.5%) and Asian (8.7%), with 14.6% self-identified as Hispanic or Latino ethnicity. Mean sensitivity (SD) was 29.1 (1.3) decibels (dB) for the 24-2 and 32.4 (1.0) dB for the 10-2 test. For the 24-2 and 10-2, mean sensitivity (SD) age-related changes averaged- 0.06 (0.01) dB and- 0.05 (0.01) dB per year, respectively. The normal range of pointwise threshold sensitivity increased with eccentricity and showed asymmetry around the mean, particularly notable in the 24-2 test. Mean (SD) binocular test duration was 3.18 (0.38) minutes (1 minute 35 seconds per eye) for the 24-2 test and 3.58 (0.43) minutes (1 minute 47 seconds per eye) for the 10-2 test. Conclusions: An RDB for the TEMPO/IMOvifa perimeter was established, highlighting the significance of considering both age and stimulus eccentricity in interpreting threshold VF test results.
Keywords:
Perimetry
Reference database
Visual
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Ophthalmology Science cover
Ophthalmology Science
IF:
4.6
Papers:
1.2K
Citations:
1.6K

Organization

U
University of Iowa
Scholars:
2.8W
Papers: 2.3W
Citations: 600
U
University of California Berkeley
Scholars:
3.5W
Papers: 2.8W
Citations: 11.3W
S
state university of new york (suny) system
Scholars:
6.5W
Papers: 5.8W
Citations: 65
University of California System cover
University of California System
Scholars:
37.5W
Papers: 33.7W
Citations: 6.6K
S
suny optometry
Scholars:
91
Papers: 68
Citations: 0
researcher View more organizations