arrow
Return

Repaint High-Density Surface Electromyography Signal Using Denoising Diffusion Probabilistic Model

delete2025-09-02
delete0
PRE
AI
Y
Yihui Zhao
J
Jiawei Liao
F
Fang Xia
H
Hai Wang
江宁 (Ning Jiang)
何家源 (Jiayuan He)
DOI:10.1109/TBME.2025.3604527delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Objective: High-density surface electromyography (HD-sEMG) has emerged as a powerful tool for myoelectric control and activation pattern analysis. However, signal loss due to poor electrode contact and channel corruption remains a significant challenge, limiting the reliability and practical applications of HD-sEMG signals. Conventional interpolation methods fail to effectively reconstruct corrupted signals, especially when multiple adjacent channels are affected. Methods: This paper proposes a novel HD-sEMG signal reconstruction approach based on the denoising diffusion probabilistic model (DDPM) with a repaint strategy. By leveraging a U-Net structure with spatiotemporal embedding modules that effectively learn the spatial and temporal characteristics of HD-sEMG signals, the proposed method achieves high-fidelity signal reconstruction without requiring prior knowledge of corruption patterns. Results: Experimental evaluations are conducted on 6 corruption patterns with varying ratios (from 12.5% to 50%) using self-collected datasets (including an amputated subject) and a benchmark dataset. Results demonstrate that the proposed approach consistently outperforms interpolation methods (linear: 0.038 $\pm$ 0.033, cubic: 0.038 $\pm$ 0.032), generative adversarial net (GAN) (0.049 $\pm$ 0.041), and variational autoencoder (VAE) (0.068 $\pm$ 0.046) in terms of $nRMSE$ ($p < 0.001$), achieving the lowest error of 0.027 $\pm$ 0.027 averaged across all corruption ratios. For $PSNR$, the proposed approach achieves the highest mean value (35.81 $\pm$ 17.95 dB) compared to interpolation methods (linear: 33.89 $\pm$ 26.85, cubic: 33.88 $\pm$ 26.88 dB), GAN (31.08 $\pm$ 19.14 dB), and VAE (26.98 $\pm$ 18.94 dB) ($p < 0.001$). Furthermore, the proposed method maintained robust classification accuracy, achieving statistically equivalent performance to ground truth at the lower corruption ratio. Significance: The proposed HD-sEMG signal reconstruction approach offers a new solution for enhancing the fidelity and reliability of HD-sEMG signal acquisition.
Keywords:
High-density electromyography
signal reconstruction
myoelectric control
diffusion model

Journal

I
IEEE Transactions on Biomedical Engineering
IF:
4.5
Papers:
468
Citations:
2.8W

Organization

S
sichuan university
Scholars:
12.0W
Papers: 7.8W
Citations: 100