arrow
Return

Revised Motion Estimation Algorithm for PROPELLER MRI

delete2013-09-04
delete35
delete
OA
AI
J
James G. Pipe *
W
Wende N. Gibbs
Z
Zhiqiang Li
J
John P. Karis
M
Michael Schär
N
Nicholas R. Zwart
DOI:10.1002/mrm.24929delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Purpose: To introduce a new algorithm for estimating data shifts (used for both rotation and translation estimates) for motion-corrected PROPELLER MRI. The method estimates shifts for all blades jointly, emphasizing blade-pair correlations that are both strong and more robust to noise. Theory and Methods: The heads of three volunteers were scanned using a PROPELLER acquisition while they exhibited various amounts of motion. All data were reconstructed twice, using motion estimates from the original and new algorithm. Two radiologists independently and blindly compared 216 image pairs from these scans, ranking the left image as substantially better or worse than, slightly better or worse than, or equivalent to the right image. Results: In the aggregate of 432 scores, the new method was judged substantially better than the old method 11 times, and was never judged substantially worse. Conclusion: The new algorithm compared favorably with the old in its ability to estimate bulk motion in a limited study of volunteer motion. A larger study of patients is planned for future work. (C) 2013 Wiley Periodicals, Inc.
Keywords:
MRI
motion
PROPELLER
errShare
errSave
errShare
errSave
T1 weighted fat/water separated PROPELLER acquired with dual bandwidths
err2018-04-24
err8
PREAI
errRyden, Henric; Berglund, Johan; Norbeck, Ola; Avventi, Enrico; Skare, Stefan
errShare
errSave
MRI of the lung using the PROPELLER technique: Artifact reduction, better image quality and improved nodule detection
err2016-04-01
err36
PREAI
errMeier-Schroers, Michael; Kukuk, Guido; Homsi, Rami; Skowasch, Dirk; Schild, Hans Heinz; Thomas, Daniel
errShare
errSave
AI-based motion artifact severity estimation in undersampled MRI allowing for selection of appropriate reconstruction models
err2024-01-03
err2
errOAAI
errBeljaards, Laurens; Pezzotti, Nicola; Rao, Chinmay; Doneva, Mariya; van Osch, Matthias J. P.; Staring, Marius
errShare
errSave
An MRI-Compatible Platform for One-Dimensional Motion Management Studies in MRI
err2015-10-23
err4
errOAAI
errNofiele, Joris; Yuan, Qing; Kazem, Mohammad; Tatebe, Ken; Torres, Quinn; Sawant, Amit; Pedrosa, Ivan; Chopra, Rajiv
errShare
errSave

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.8W

Organization

P
philips
Scholars:
58
Papers: 35
Citations: 1.5K
B
Barrow Neurological Institute
Scholars:
101
Papers: 59
Citations: 856
Cited Papers

Cited Papers

Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-Cartesian external calibration data driven parallel imaging
err2012-03-02
err15
errOAAI
errHolmes, James H.; Beatty, Philip J.; Rowley, Howard A.; Li, Zhiqiang; Gaddipati, Ajeetkumar; Zhao, Xiaoli; Busse, Reed F.; Brittain, Jean H.
errShare
errSave
Rapid PROPELLER-MRI: A combination of iterative reconstruction and under-sampling
err2012-06-11
err5
errOAAI
errTamhane, Ashish A.; Arfanakis, Konstantinos; Anastasio, Mark; Guo, Xiaodong; Vannier, Michael; Gao, Jia-Hong
errShare
errSave
Efficient sample density estimation by combining gridding and an optimized kernel
err2011-06-17
err88
errOAAI
errZwart, Nicholas R.; Johnson, Kenneth O.; Pipe, James G.
errShare
errSave
no more