Robust variable step P&O algorithm based MPPT for PMSG wind generation system using estimated wind speed compensation technique

delete2023-12-01
delete7
PRE
AI
I
Ilham Toumi
A
Amira Boulmaiz
B
Billel Meghni *
O
Oussama Hachana
DOI:10.1016/j.seta.2023.103420delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
To expedite the cost recovery of the wind energy conversion system (WECS), maximizing power availability at all times is of utmost importance. Therefore, the primary objective of Maximum Power Point Tracking (MPPT) algorithms is to optimize power output by ensuring the achievement of maximum power under varying wind speeds. The perturbation and observation algorithm are widely recognized as the most well-known technique used in wind energy conversion systems (WECS) due to its versatility. Although this algorithm is valued for its simplicity and cost-effectiveness, it does have a significant drawback. Peculiarly, it is insensitive to fluctuations in instantaneous wind speed conditions and lacks accurate step size estimation. To address these limitations, a novel approach called the Robust Variable Step P&O (RVS-P&O) technique has been proposed. The RVS-P&O technique aims to overcome the aforementioned drawbacks. The control strategy employed by the proposed RVS-P&O-MPPT algorithm is based on three fundamental concepts: a new normalization of the selection of the step size, a novel correction procedure to estimate the power variation and wind speed estimation (WSE) algorithm based on the artificial neural network (ANN) controller. Simulations have been carried out by means of MATLAB/Simulink environment. The findings indicate the superiority of the proposed RVS-P&O algorithm compared to several P&O implementations: fixed Large Step (LS), fixed Small Step (SS), Variable Step (VS) and Modified (M)-P&O. The developed algorithm allows reaching 99.79% of wind energy conversion system (WECS) efficiency. This allows obtaining an enhancement of 2.19% in comparison to VS-P&O technique which is the most competing algorithm. Further, the response speed is clearly improved compared to the various P&O versions, as the settling time (sec) is of 0.0074 while that of VS and M-P&O is of 0.0157 and 0.0079, respectively. Indeed, to enhance the quality of the injected power into the grid, a Second Order Sliding Mode Controller (SOSMC) based Super Twisting Algorithm (STA) is proposed. The results show the suggested technique outperforms the PI and First Order (FO)-SMC for current THD minimization by attenuating the odd harmonics without chattering phenomenon.
Keywords:
Maximum power point tracking
Robust variable step-perturb & observe
Second order sliding mode controller
Step Size selection normalization and artificial
neural network (ANN)

Journal

Sustainable Energy Technologies and Assessments cover
Sustainable Energy Technologies and Assessments
IF:
7
Papers:
4.7K
Citations:
2.2W

Organization

U
universite kasdi merbah ouargla
Scholars:
761
Papers: 477
Citations: 2
U
universite badji mokhtar - annaba
Scholars:
1.7K
Papers: 1.2K
Citations: 0
Cited Papers

Cited Papers

Breast cancer survivors
err1993-12-01
err0
PREAI
errGwen Wyatt; Margot E. Kurtz; Michelle Liken
errShare
errSave
General review and classification of different MPPT Techniques
err2017-02-01
err351
PREAI
errKarami, Nabil; Moubayed, Nazih; Outbib, Rachid
errShare
errSave
errShare
errSave
PSO-based MPPT control of wind-driven Self-Excited Induction Generator for pumping system
err2016-09-01
err37
errOAAI
errZeddini, Mohamed. Ali; Pusca, Remus; Sakly, Anis; Mimouni, M. Faouzi
errShare
errSave
Leukocytosis is a risk factor for thrombosis in essential thrombocythemia: interaction with treatment, standard risk factors, and Jak2 mutation status
err2006-11-16
err0
errOAAI
errAlessandra Carobbio; Guido Finazzi; Vittoria Guerini; Orietta Spinelli; Federica Delaini; Roberto Marchioli; Giovanna Borrelli; Alessandro Rambaldi; Tiziano Barbui
errShare
errSave
researcher View more