arrow
Return

Salient Sub-Second Separations

delete2016-08-16
delete98
delete
OA
AI
M
M. Farooq Wahab
R
Rasangi M. Wimalasinghe
Y
Yadi Wang
C
Chandan L. Barhate
D
Darshan C. Patel
D
Daniel W. Armstrong *
DOI:10.1021/acs.analchem.6b02260delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Sub-second liquid chromatography in very short packed beds is demonstrated as a broad proof of concept for chiral, achiral, and HILIC separations of biologically important molecules. Superficially porous particles (SPP, 2.7 mu m) of different surface chemistries, namely, teicoplanin, cyclofructan, silica, and quinine, were packed in 0.5-cm-long columns for separating different classes of compounds. Several issues must be addressed to obtain the maximum performance of 0.5 cm columns with reduced plate heights of 2.6 to 3.0. Modified UHPLC hardware can be used to obtain sub-second separations provided extra-column dispersion is minimized and sufficient data acquisition rates are used. Further, hardware improvements will be needed to take full advantage of faster separations. The utility of power transform, which is already employed in certain chromatography detectors, is shown to be advantageous for sub-second chromatography. This approach could prove to be beneficial in fast screening and two-dimensional liquid chromatography.
Keywords:
COMPREHENSIVE 2-DIMENSIONAL SEPARATIONS
SUPERFICIALLY POROUS PARTICLES
PRESSURE LIQUID-CHROMATOGRAPHY
SHEAR-DRIVEN CHROMATOGRAPHY
CHIRAL STATIONARY PHASES
HIGH-EFFICIENCY
SIZE DISTRIBUTION
PERFORMANCE
ELECTROPHORESIS
EXCHANGERS
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Analytical Chemistry cover
Analytical Chemistry
IF:
6.7
Papers:
4.7W
Citations:
15.9W

Organization

U
university of texas system
Scholars:
18.5W
Papers: 15.6W
Citations: 210
Cited Papers

Cited Papers

k-Nearest Neighbour method in functional nonparametric regression
err2009-05-01
err0
PREAI
errFlorent Burba; Frédéric Ferraty; Philippe Vieu
errShare
errSave
Development of New HPLC Chiral Stationary Phases Based on Native and Derivatized Cyclofructans
err2009-12-14
err185
PREAI
errSun, Ping; Wang, Chunlei; Breitbach, Zachary S.; Zhang, Ying; Armstrong, Daniel W.
errShare
errSave
Subsecond Electrophoretic Separations from Droplet Samples for Screening of Enzyme Modulators
err2014-10-02
err44
errOAAI
errGuetschow, Erik D.; Steyer, Daniel J.; Kennedy, Robert T.
errShare
errSave
Transmission electron microscopy and image simulation study of CuAu domains in CuInS2 epitaxial layers
err2003-05-01
err0
PREAI
errB. Barcones; A. Romano-Rodrı́guez; J. Arbiol; J. Álvarez-Garcı́a; A. Pérez-Rodrı́guez; J.R. Morante; R. Scheer
errShare
errSave
Subsecond chiral separations on a microchip
err2004-11-26
err72
PREAI
errPiehl, N; Ludwig, M; Belder, D
errShare
errSave
Sub-second liquid chromatographic separations by means of shear-driven chromatography
err2002-12-01
err43
PREAI
errClicq, D; Vervoort, N; Vounckx, R; Ottevaere, H; Buijs, J; Gooijer, C; Ariese, F; Baron, GV; Desmet, G
errShare
errSave
researcher View more