arrow
Return

Sampling errors in projection reconstruction MRI

delete2005-12-12
delete22
PRE
AI
J
Joseph, PM *
DOI:10.1002/mrm.1910400317delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. it has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruction, and that the usual Nyquist criterion is inadequate. This paper examines this problem, with the conclusion that the Nyquist sampling criterion is adequate to avoid aliasing effects, provided that a band-limited interpolation is used in k-space. This procedure is motivated by analysis of the PR technique as it is commonly implemented in x-ray computed tomography. A related problem is shown to be the construction of a filter function in k-space that gives proper weight to the low spatial frequencies. It is shown that a simple \k\ filter does not satisfy this requirement, and a procedure for deriving a suitable filter is described. The methods are tested in simulated PR profiles of circular disks of two different sizes. it is shown that the combination of the two new methods gives virtually perfect reconstruction for disks up to the size implied by the Nyquist limit.
Keywords:
RESONANCE

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

No organization information available
Cited Papers

Cited Papers

Modeling of electric vehicle fast charging station and impact on network voltage
err2013-11-01
err0
PREAI
errJia Ying Yong; Vigna K. Ramachandaramurthy; Kang Miao Tan; Atputharajah Arulampalam; Jeyraj Selvaraj
errShare
errSave
Building permanently optically active particles from an absolutely achiral polymer
err2022-01-01
err0
PREAI
errZixiang He; Tengfei Miao; Xiaoxiao Cheng; Haotian Ma; Yafei Ma; Wei Zhang; Xiulin Zhu
errShare
errSave
errShare
errSave
Discovering the Intrinsic Causes of Dendrite Formation in Zinc Metal Anodes: Lattice Defects and Residual Stress
err2023-02-28
err0
PREAI
errChunlin Xie; Shengfang Liu; Zefang Yang; Huimin Ji; Shuhan Zhou; Hao Wu; Chao Hu; Yougen Tang; Xiaobo Ji; Qi Zhang; Haiyan Wang
errShare
errSave
Miniaturized MR-compatible ultrasound system for real-time monitoring of acoustic effects in mice using high-resolution MRI
err2023-08-01
err0
errOAAI
errSubeen Kim; Yehhyun Jo; Geun Ho Im; Chanhee Lee; Chaerin Oh; Geon Kook; Seong-Gi Kim; Hyunjoo J. Lee
errShare
errSave
Radial BURST imaging
err2005-12-12
err9
PREAI
errJakob, PM; Kober, F; Haase, A
errShare
errSave
researcher View more