Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging

delete2017-09-14
delete21
PRE
AI
F
Feiyu Chen *
V
Valentina Taviani
J
Jonathan I. Tamir
J
Joseph Y. Cheng
T
Tao Zhang
Q
Qiong Song
B
Brian A. Hargreaves
J
John M. Pauly
S
Shreyas Vasanawala
DOI:10.1002/jmri.25853delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BackgroundIt is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T-2 decay and partial-Fourier acquisition. PurposeTo develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Study TypeProspective controlled clinical trial. SubjectsWith Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). Field Strength/SequenceA wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5x) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. AssessmentImage quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. Statistical TestsA Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. ResultsWave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P < 0.003). No significant difference was observed in relation to other features (P = 0.11). An average of 21% decrease in scan time was achieved using the proposed method. Data ConclusionWave-encoded variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. Level of Evidence: 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966.
Keywords:
wave encoding
variable-density sampling
single-shot fast spin echo
self-calibration
parallel imaging
compressed sensing
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Journal of Magnetic Resonance Imaging cover
Journal of Magnetic Resonance Imaging
IF:
3.5
Papers:
9.9K
Citations:
2.0W

Organization

G
General Electric
Scholars:
4.4K
Papers: 3.4K
Citations: 2
U
University of California Berkeley
Scholars:
3.5W
Papers: 2.8W
Citations: 11.3W
S
Stanford University
Scholars:
9.6W
Papers: 8.2W
Citations: 17.0W
University of California System cover
University of California System
Scholars:
37.5W
Papers: 33.7W
Citations: 6.6K
researcher View more organizations