arrow
Return

Self-reported Home Exercise Adherence: A Validity and Reliability Study Using Concealed Accelerometers

delete2018-12-01
delete61
PRE
AI
P
Philippa Nicolson *
R
Rana S. Hinman
T
Tim V. Wrigley
P
Paul W. Stratford
K
Kim L. Bennell
DOI:10.2519/jospt.2018.8275delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND: Accurate measurement of adherence to prescribed exercise programs is essential. Diaries and self-report rating scales are commonly used, yet little evidence exists to demonstrate their validity and reliability. OBJECTIVES: To examine the concurrent validity of adherence to home strengthening exercises measured by (1) exercise diaries and (2) a self-report rating scale, compared to adherence measured using an accelerometer concealed in an ankle cuff weight. Test-retest reliability of the self-report rating scale was also assessed. METHODS: In this clinical measurement study, 54 adults aged 45 years or older with self-reported chronic knee pain were prescribed a home quadriceps-strengthening program. Over 12 weeks, participants completed paper exercise diaries and, at appointments every 2 weeks, rated their adherence on an 11-point numeric rating scale. A triaxial accelerometer was concealed in the ankle cuff weight used for exercises. Self-reported adherence rating scale data over each 2-week period were analyzed using descriptive statistics, the Wilcoxon signed-rank test, and a Bland-Altman plot to assess agreement, Spearman correlations for validity, and intraclass correlation coefficients for test-retest reliability. RESULTS: Exercise adherence was significantly overestimated in diaries during the 12 weeks (diary median, 220 exercises; accelerometer, 176; P<.001) and was moderately correlated with accelerometer data (r = 0.52; 95% confidence interval: 0.26, 0.69). A Bland-Altman plot indicated large between-participant variability in agreement between these measures. Self-reported adherence showed poor to fair correlations with accelerometer data (mean r = 0.23-0.39), and less than acceptable reliability (intraclass correlation coefficient = 0.79; lower 1-sided 95% confidence limit, 0.68). CONCLUSION: Exercise diaries showed questionable validity and variable levels of agreement compared with accelerometer-measured exercise completion. A self-reported adherence rating scale had limited validity and less than acceptable test-retest reliability.
Keywords:
clinical measurement
exercise diary
self-report scale
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Journal of Orthopaedic and Sports Physical Therapy cover
Journal of Orthopaedic and Sports Physical Therapy
IF:
5.8
Papers:
2.9K
Citations:
1.0W

Organization

M
McMaster University
Scholars:
3.6W
Papers: 3.3W
Citations: 4.4W
U
university of melbourne
Scholars:
5.7W
Papers: 5.4W
Citations: 69