arrow
Return

Small nodule detectability evaluation using a generalized scan-statistic model

delete2006-11-15
delete40
PRE
AI
L
Lucreţiu M. Popescu *
R
R.M. Lewitt
DOI:10.1088/0031-9155/51/23/020delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
In this paper is investigated the use of the scan statistic for evaluating the detectability of small nodules in medical images. The scan-statistic method is often used in applications in which random fields must be searched for abnormal local features. Several results of the detection with localization theory are reviewed and a generalization is presented using the noise nodule distribution obtained by scanning arbitrary areas. One benefit of the noise nodule model is that it enables determination of the scan-statistic distribution by using only a few image samples in a way suitable both for simulation and experimental setups. Also, based on the noise nodule model, the case of multiple targets per image is addressed and an image abnormality test using the likelihood ratio and an alternative test using multiple decision thresholds are derived. The results obtained reveal that in the case of low contrast nodules or multiple nodules the usual test strategy based on a single decision threshold underperforms compared with the alternative tests. That is a consequence of the fact that not only the contrast or the size, but also the number of suspicious nodules is a clue indicating the image abnormality. In the case of the likelihood ratio test, the multiple clues are unified in a single decision variable. Other tests that process multiple clues differently do not necessarily produce a unique ROC curve, as shown in examples using a test involving two decision thresholds. We present examples with two-dimensional time-of-flight (TOF) and non-TOF PET image sets analysed using the scan statistic for different search areas, as well as the fixed position observer.
Keywords:
OBSERVER-PERFORMANCE
EXCURSION SETS
SIGNAL
METHODOLOGY
LOCATION
CURVES
IMAGES
TUBES
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Physics in Medicine and Biology cover
Physics in Medicine and Biology
IF:
3.4
Papers:
1.4W
Citations:
3.1W

Organization

No organization information available
Cited Papers

Cited Papers

errShare
errSave
Spinal cord injury: an epidemiologic perspective
err1979-07-01
err0
errOAAI
errPhilip R Fine; Keith V Kuhlemeier; Michael J DeVivo; Samuel L Stover
errShare
errSave
errShare
errSave
ERAP1 and ERAP2 Gene Variations Influence the Risk of Psoriatic Arthritis in Romanian Population
err2017-01-12
err0
PREAI
errOlivia M. Popa; Marius Cherciu; Laura I. Cherciu; Monica I. Dutescu; Mihai Bojinca; Violeta Bojinca; Constantin Bara; Luis O. Popa
errShare
errSave
A comparison of human and model observers in multislice LROC studies
err2005-02-01
err112
PREAI
errGifford, HC; King, MA; Pretorius, PH; Wells, RG
errShare
errSave
researcher View more