Return
Soft Microelectrode Linear Array for Scanning Electrochemical Microscopy
DOI:10.1021/ac1019304.png)
Abstract
En 中文
A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime. Similar to previous reports, the soft microelectrode array was fabricated by ablating microchannels on a polyethylene terephthalate (PET) film and filling them with carbon ink. Improvements have been achieved by using a 5 mu m thick Parylene coating that allows for smaller working distances, as the probe was mounted with the Parylene coating facing the sample surface. Additionally, the application of a SECM holder allows scanning in contact regime with a tilted probe, reducing the topographic effects and assuring the probe bending direction. The main advantage of the soft microelectrode array is the considerable decrease in the experimental time needed for imaging large sample areas. Additionally, soft microelectrode arrays are very stable and can be used several times, since the electrode surface can be regenerated by blade cutting. Cyclic voltammograms and approach curves were recorded in order to assess the electrochemical properties of the device. An SECM image of a gold on glass chip was obtained with high resolution and sensitivity, proving the feasibility of soft tnicroelectrode arrays to detect localized surface activity. Finite element method (FEM) simulations were performed in order to establish the effect of diffusion layer overlapping between neighboring electrodes on the respective approach curves.
Keywords:
NUMERICAL SIMULATIONS
LOCALIZED CORROSION
SIMULTANEOUS SECM
CHARGE-TRANSFER
INTEGRATED AFM
IN-SITU
TIP
SURFACES
PROBE
DIFFUSION
AI Summary
Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.
Journal
IF:
6.7
Papers:
4.7W
Citations:
15.9W
Organization
Cited Papers
Dual microelectrodes for distance control and detection of nitric oxide from endothelial cells by means of scanning electrochemical microscope
ANALYTICAL CHEMISTRY
IF6.7
Disk-generation/ring-collection scanning electrochemical microscopy: Theory and application
ANALYTICAL CHEMISTRY
IF6.7
Addressable microelectrode arrays: Characterization by imaging with scanning electrochemical microscopy
ANALYTICAL CHEMISTRY
IF6.7
Investigating the concept of diffusional independence. Potential step transients at nano- and micro-electrode arrays: theory and experiment
ANALYST
IF3.3
Fabrication and characterization of probes for combined scanning electrochemical/optical microscopy experiments
ANALYTICAL CHEMISTRY
IF6.7
Simulation in electrochemistry using the finite element method part 2: scanning electrochemical microscopy
ELECTROCHIMICA ACTA
IF5.6