1
Return

Solar Still Unit as a Component of Domestic Wastewater Treatment in Isolated Rural Communities: A Case Study in Colombia

delete2026-07-08
delete0
delete
OA
AI
C
Carlos Mauricio Meza
F
Franco Hernan Gomez *
K
Kelly Cristina Torres
O
Oscar Orlando Porras
A
Alessandro Abbà
M
Marta Domini
S
Sabrina Sorlini
M
Mentore Vaccari
DOI:10.3390/chemengineering10070086delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
The use of non-conventional systems for domestic wastewater management has gained attention in rural areas of the Global South, where centralised infrastructure is often limited. This study presents the design, construction, and pilot-scale evaluation of a solar still unit operated under passive and photovoltaic-assisted active modes as a separation and polishing component for domestic wastewater from a rural site in Barrancabermeja, Colombia. Performance was assessed through physicochemical and microbiological characterisation of influent wastewater and treated condensate, together with hourly monitoring of distillate production, water temperature, glass-cover temperature, and ambient conditions. Under passive operation, a theoretical distillation model was applied, empirically adjusted, and evaluated using MAE, RMSE, MAPE, and R2. Under the tested conditions, indicative within-mode reductions reached 80.9% and 89.3% for chemical oxygen demand (COD), 95.6% and 93.8% for biochemical oxygen demand (BOD5), and 94.0% and 94.4% for total suspended solids (TSS) under passive and active modes, respectively. Microbial indicators showed minimum estimated reductions above 99.9%, with faecal coliforms reduced to very low levels in passive mode and not detected in the analysed active-mode condensate sample. Maximum daily condensate production reached 1.445 L m−2 day−1 in passive mode and 2.262 L m−2 day−1 in active mode, confirming the low-flow nature of the unit. Approximately 50% of daily production occurred between 12:00 and 15:00 h. The model reproduced the main diurnal production pattern, although empirical correction was required. Overall, the unit may improve condensate quality under pilot-scale conditions and shows potential as a polishing component within decentralised, low-flow treatment trains.
Keywords:
wastewater
water quality
solar thermal
solar still
decentralised sanitation
rural
WASH technologies

Journal

ChemEngineering cover
ChemEngineering
IF:
3.4
Papers:
328
Citations:
1.6K

Organization

U
university of brescia
Scholars:
1.4K
Papers: 629
Citations: 0
I
instituto universitario de la paz-unipaz
Scholars:
5
Papers: 3
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers