arrow
Return

Sparse Spectral Deconvolution Algorithm for Noncartesian MR Spectroscopic Imaging

delete2013-03-13
delete14
PRE
AI
S
Sampada Bhave
M
Mathews Jacob *
DOI:10.1002/mrm.24693delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
PurposeTo minimize line shape distortions and spectral leakage artifacts in MR spectroscopic imaging (MRSI). MethodsA spatially and spectrally regularized non-Cartesian MRSI algorithm that uses the line shape distortion priors, estimated from water reference data, to deconvolve the spectra is introduced. Sparse spectral regularization is used to minimize noise amplification associated with deconvolution. A spiral MRSI sequence that heavily oversamples the central k-space regions is used to acquire the MRSI data. The spatial regularization term uses the spatial supports of brain and extracranial fat regions to recover the metabolite spectra and nuisance signals at two different resolutions. Specifically, the nuisance signals are recovered at the maximum resolution to minimize spectral leakage, while the point spread functions of metabolites are controlled to obtain acceptable signal-to-noise ratio. ResultsThe comparisons of the algorithm against Tikhonov regularized reconstructions demonstrates considerably reduced line-shape distortions and improved metabolite maps. ConclusionThe proposed sparsity constrained spectral deconvolution scheme is effective in minimizing the line-shape distortions. The dual resolution reconstruction scheme is capable of minimizing spectral leakage artifacts. Magn Reson Med 71:469-476, 2014. (c) 2013 Wiley Periodicals, Inc.
Keywords:
lineshape distortions
spiral
non-Cartesian
magnetic resonance spectroscopic imaging (MRSI)
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

U
University of Iowa
Scholars:
2.8W
Papers: 2.3W
Citations: 600
Cited Papers

Cited Papers

Single-Shot Magnetic Resonance Spectroscopic Imaging with Partial Parallel Imaging
err2008-12-18
err37
errOAAI
errPosse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan
errShare
errSave
Bayesian k-Space-Time Reconstruction of MR Spectroscopic Imaging for Enhanced Resolution
err2010-07-01
err22
errOAAI
errKornak, John; Young, Karl; Soher, Brian J.; Maudsley, Andrew A.
errShare
errSave
Mapping of Brain Metabolite Distributions by Volumetric Proton MR Spectroscopic Imaging (MRSI)
err2008-12-28
err243
errOAAI
errMaudsley, A. A.; Domenig, C.; Govind, V.; Darkazanli, A.; Studholme, C.; Arheart, K.; Bloomer, C.
errShare
errSave
The Influence of Different External Fields on Aging Kinetics of 2219 Aluminum Alloy
err2016-08-26
err0
errOAAI
errLihua Zhan; Wenke Li; Qiangqiang Ma; Lingfeng Liu
errShare
errSave
Volumetric spectroscopic imaging with spiral-based k-space trajectories
err2005-12-12
err204
PREAI
errAdalsteinsson, E; Irarrazabal, P; Topp, S; Meyer, C; Macovski, A; Spielman, DM
errShare
errSave
Improved model-based magnetic resonance spectroscopic imaging
err2007-10-01
err28
PREAI
errJacob, Mathews; Zhu, Xiaoping; Ebel, Andreas; Schuff, Norbert; Liang, Zhi-Pei
errShare
errSave
Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction
err2008-03-27
err27
errOAAI
errMayer, Dirk; Kim, Dong-Hyun; Spielman, Daniel M.; Bammer, Roland
errShare
errSave
Accelerated proton echo planar spectroscopic Imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil
err2008-04-21
err63
PREAI
errTsai, Shang-Yueh; Otazo, Ricardo; Posse, Stefan; Lin, Yi-Ru; Chung, Hsiao-Wen; Wald, Lawrence L.; Wiggins, Graham C.; Lin, Fa-Hsuan
errShare
errSave
researcher View more