Abstract

Abstract

En 中文
Static computed tomography (CT) is an advanced 3D measurement technology. It offers key instrumentation advantages by reducing motion-induced artifacts, preserving measurement accuracy, and lowering radiation doses- critical factors for precision systems. This capability is particularly crucial for imaging moving organs such as the heart. This study introduces a novel Multi-Array Stationary CT (MASCT) imaging architecture. Utilizing cold- cathode carbon nanotube X-ray sources, the proposed architecture achieves dual innovations in temporal and spatial resolution, advancing stationary CT instrument design. Firstly, the X-ray source's rapid response allows for swift data acquisition. Coupled with its low power consumption and compact form factor, these characteristics collectively facilitate high temporal resolution, meeting the demands of dynamic imaging. Second, the densely arranged source array enhances angular resolution, while the z-axis MAS configuration extends scanning capacity for elongated objects, thereby expanding spatial resolution across multiple dimensions. To address practical implementation challenges, we incorporate iterative reconstruction algorithms to solve limited-angle problem, achieving diagnostically acceptable image quality. The feasibility of our multi-array X-ray source-based static CT system is rigorously validated through both numerical simulations and physical experiments.
Keywords:
cold cathode
carbon nanotub
stationary CT
imaging system
iterative reconstruction

Journal

J
Journal of X-ray Science and Technology
IF:
1.4
Papers:
39
Citations:
1.1K

Organization

N
nanchang university
Scholars:
9.2K
Papers: 2.5K
Citations: 0
S
Sun Yat sen University
Scholars:
7.7K
Papers: 2.0K
Citations: 1.8W
Cited Papers

Cited Papers

Rectangular Fixed-Gantry CT Prototype: Combining CNT X-Ray Sources and Accelerated Compressed Sensing-Based Reconstruction
err2014-01-01
err47
errOAAI
errGonzales, Brian; Spronki, Derrek; Cheng, Yuan; Tucker, Andrew W.; Beckman, Moritz; Zhou, Otto; Lu, Jianping
errShare
errSave
errShare
errSave
X-ray scatter correction for multi- source interior computed tomography
err2017-01-19
err9
PREAI
errGong, Hao; Yan, Hao; Jia, Xun; Li, Bin; Wang, Ge; Cao, Guohua
errShare
errSave
Two Monte Carlo-based simulators for imaging-system modeling and projection simulation of flat-panel X-ray source
err2024-07-09
err0
PREAI
errQi, Meng-Ke; He, Ting; Zhou, Yi-Wen; Kang, Jing; Pan, Zeng-Xiang; Kang, Song; Wu, Wang-Jiang; Chen, Jun; Zhou, Ling-Hong; Xu, Yuan
errShare
errSave
Diffusion Kernel Attention Network for Brain Disorder Classification
err2022-10-01
err23
PREAI
errZhang, Jianjia; Zhou, Luping; Wang, Lei; Liu, Mengting; Shen, Dinggang
errShare
errSave
HIGH-SPEED 3-DIMENSIONAL X-RAY COMPUTED-TOMOGRAPHY - THE DYNAMIC SPATIAL RECONSTRUCTOR
err1983-01-01
err105
PREAI
errROBB, RA; HOFFMAN, EA; SINAK, LJ; HARRIS, LD; RITMAN, EL
errShare
errSave
Half-scan cone-beam CT fluoroscopy with multiple x-ray sources
err2001-07-06
err73
PREAI
errLiu, Y; Liu, H; Wang, Y; Wang, G
errShare
errSave
Feasibility of a stationary head CT scanner using a CNT x-ray source array
err2020-03-16
err0
PREAI
errDerrek Spronk; Yueting Lu; Christy Inscoe; Alex Billingsley; Yueh Z. Lee; Jianping Lu; Otto Zhou
errShare
errSave
researcher View more