arrow
Return

Strategy for constructing robust multivariate calibration models

delete1999-09-01
delete113
PRE
AI
S
Swierenga, H
D
de Weijer, AP
V
van Wijk, RJ
B
Buydens, LMC
DOI:10.1016/S0169-7439(99)00028-3delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
In multivariate calibrations usually a minimal residual error in the model's predictions is aimed at, while generally less attention is paid to the robustness of the model with respect to changes in instrumentation, laboratory conditions, or sample composition. In this paper, we propose a strategy for selecting a multivariate calibration model which possesses a small pre diction error and, simultaneously, is less sensitive to the above-mentioned variations. The strategy is applied to calibration models used to predict the density of poly(ethylene terephthalate) (PET) yarns from the Raman spectra. The strategy implies that spectra of calibration samples are measured under circumstances under which the application will be implemented, and spectra of a smaller set under different conditions (variations in ambient temperature, laser power, and laser frequency) according to an experimental design. The prediction results of the calibration model are used in a ruggedness test in order to test the sensitivity. In this study various calibration models using different spectral preprocessing techniques are tested. These ruggedness results together with the prediction error are used to select a good model. Moreover, it is possible in this way to provide the boundaries for the experimental conditions, where the model is valid. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords:
multivariate calibration model
prediction error
poly(ethylene terephthalate)
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Chemometrics and Intelligent Laboratory Systems cover
Chemometrics and Intelligent Laboratory Systems
IF:
3.8
Papers:
4.6K
Citations:
1.2W

Organization

No organization information available
Cited Papers

Cited Papers

errShare
errSave
errShare
errSave
Chemical and Chemotaxonomical Studies of Filices. LXXII. Chemical Studies on the Constituents of Odontosoria gymnogrammoides CHRIST
err1987-01-01
err0
errOAAI
errKAZUYUKI HORI; TOSHIKO SATAKE; HIROMI YAMAGUCHI; YASUHISA SAIKI; TAKAO MURAKAMI; CHIUMING CHEN
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Standardization of near-infrared spectrometric instruments
err1996-03-15
err241
PREAI
errBouveresse, E; Hartmann, C; Massart, DL; Last, IR; Prebble, KA
errShare
errSave
researcher View more