arrow
Return

Successive projections algorithm combined with uninformative variable elimination for spectral variable selection

delete2008-04-01
delete225
PRE
AI
S
Shengfeng Ye
D
Dong Wang
S
Shungeng Min *
DOI:10.1016/j.chemolab.2007.11.005delete
deleteOriginal
deleteShare
deleteSave
Abstract

Abstract

En 中文
The UVE - SPA method, successive projections algorithm (SPA) combined with uninformative variable elimination (UVE) is proposed as a novel variable selection approach for multivariate calibration. UVE is used to select informative variables, and SPA is followed to select variables with minimum redundant information from the informative variables. The proposed method was applied to near-infrared (NIR) reflectance data for analysis of nicotine in tobacco lamina and NIR transmission data for active pharmaceutical ingredient (API) in single tablet. On the aspect of elimination of uninformative variables, the effect of UVE using first derivative spectra was better than that of using raw spectra. In terms of variable selection, fewer variables with better performance were selected by UVE - SPA method than by direct SPA method. For NIR spectral analysis of nicotine in tobacco lamina, the number of variables selected from 3001 spectral variables reduced from 48 by direct SPA to 35 by UVE - SPA, and the root mean squared error of prediction set (RMSEP) of the corresponding MLR models decreased from 0.174 (%, mg/mg) to 0.160. For NIR spectral analysis of API in each tablet, the number of variables selected from 650 spectral variables reduced from 46 by direct SPA to 17 by UVE - SPA, and RMSEP of the corresponding multiple linear regression (MLR) models decreased from 0.842 (%, mg/mg) to 0.473. MLR model using variables selected by UVE - SPA had better prediction performance than full-spectrum partial least-squares (PLS) model, and comparable to PLS model of UVE. (c) 2007 Elsevier B.V. All rights reserved.
Keywords:
successive projections algorithm
uninformative variable elimination
variable selection
near-infrared spectroscopy
multivariate calibration

Journal

Chemometrics and Intelligent Laboratory Systems cover
Chemometrics and Intelligent Laboratory Systems
IF:
3.8
Papers:
4.6K
Citations:
1.2W

Organization

C
china agricultural university
Scholars:
5.1W
Papers: 3.0W
Citations: 43
Cited Papers

Cited Papers

Elimination of uninformative variables for multivariate calibration
err1996-11-01
err953
PREAI
errCentner, V; Massart, DL; deNoord, OE; deJong, S; Vandeginste, BM; Sterna, C
errShare
errSave
Evaluation of a new in-clinic method for the detection of canine heartworm antigen
err2011-05-01
err0
PREAI
errAlice C.Y. Lee; Dwight D. Bowman; Araceli Lucio-Forster; Melissa J. Beall; Janice L. Liotta; Ray Dillon
errShare
errSave
Robust modeling for multivariate calibration transfer by the successive projections algorithm
err2005-03-01
err60
PREAI
errHonorato, FA; Galvao, RKH; Pimentel, MF; Neto, BD; Araújo, MCU; de Carvalho, FR
errShare
errSave
Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibration
errANALYST
IF3.3
err2003-01-01
err115
PREAI
errBreitkreitz, MC; Raimundo, IM; Rohwedder, JJR; Pasquini, C; Dantas, HA; José, GE; Araújo, MCU
errShare
errSave
The successive projections algorithm for variable selection in spectroscopic multicomponent analysis
err2001-07-01
err1.2K
PREAI
errAraújo, MCU; Saldanha, TCB; Galvao, RKH; Yoneyama, T; Chame, HC; Visani, V
errShare
errSave
researcher View more