Abstract

Abstract

En 中文
In diffusion tensor imaging (DTI) an effective diffusion tensor in each voxel is measured by using a set of diffusion-weighted images (DWIs) in which diffusion gradients are applied in a multiplicity of oblique directions. However, to estimate the diffusion tensor accurately, one must account for the effects of all imaging and diffusion gradient pulses on each signal echo, which are embodied in the b matrix. For DTI to be practical clinically, one must also acquire DWIs rapidly and free of motion artifacts, which is now possible with diffusion-weighted echo-planar imaging (DW-EPI). An analytical expression for the b matrix of a general DW-EPI pulse sequence is presented and then validated experimentally by measuring the diffusion tensor in an isotropic phantom whose diffusivity is already known. The b matrix is written in a convenient tabular form as a sum of individual pair-wise contributions arising from gradient pulses applied along parallel and perpendicular directions. While the contributions from readout and phase-encode gradient pulse trains are predicted to have a negligible effect on the echo, the contributions from other imaging and diffusion gradient pulses applied in both parallel and orthogonal directions are shown to be significant in our sequence. in general, one must understand and account for the multiplicity of interactions between gradient pulses and the echo signal to ensure that diffusion tensor imaging is quantitative.
Keywords:
MRI
b matrix
EPI
diffusion tensor
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

No organization information available
Cited Papers

Cited Papers

DIFFUSION-WEIGHTED MR IMAGING OF ANISOTROPIC WATER DIFFUSION IN CAT CENTRAL-NERVOUS-SYSTEM
errRADIOLOGY
IF15.2
err1990-08-01
err1.0K
PREAI
errMOSELEY, ME; COHEN, Y; KUCHARCZYK, J; MINTOROVITCH, J; ASGARI, HS; WENDLAND, MF; TSURUDA, J; NORMAN, D
errShare
errSave
ECHO-PLANAR IMAGING OF INTRAVOXEL INCOHERENT MOTION
errRADIOLOGY
IF15.2
err1990-11-01
err510
PREAI
errTURNER, R; LEBIHAN, D; MAIER, J; VAVREK, R; HEDGES, LK; PEKAR, J
errShare
errSave
Microsurgical Removal of Olfactory Groove Meningiomas via the Pterional Approach
err2008-03-03
err0
errOAAI
errCarlo Schaller; Veit Rohde; Werner Hassler
errShare
errSave
Characterization of Sulfoxygenation and Structural Implications of Human Flavin-Containing Monooxygenase Isoform 2 (FMO2.1) Variants S195L and N413K
err2009-08-01
err0
errOAAI
errSharon K. Krueger; Marilyn C. Henderson; Lisbeth K. Siddens; Jonathan E. VanDyke; Abby D. Benninghoff; P. Andrew Karplus; Bjarte Furnes; Daniel Schlenk; David E. Williams
errShare
errSave
MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS
errRADIOLOGY
IF15.2
err1986-11-01
err3.2K
PREAI
errLEBIHAN, D; BRETON, E; LALLEMAND, D; GRENIER, P; CABANIS, E; LAVALJEANTET, M
errShare
errSave
The shear wave velocity structure of the heterogeneous alluvial plain of Beirut (Lebanon): combined analysis of geophysical and geotechnical data
err2014-09-09
err0
errOAAI
errNancy Salloum; Denis Jongmans; Cécile Cornou; Dalia Youssef Abdel Massih; Fadi Hage Chehade; Christophe Voisin; Armand Mariscal
errShare
errSave
researcher View more