Towards 'automated gonioscopy': a deep learning algorithm for 360° angle assessment by swept-source optical coherence tomography

delete2021-04-12
delete21
PRE
AI
N
Natalia Porporato
T
Tin A. Tun *
M
Mani Baskaran
D
Damon Wing Kee Wong
R
Rahat Husain
H
Huazhu Fu
R
Rehena Sultana
S
Shamira Perera
L
Leopold Schmetterer
T
Tin Aung
DOI:10.1136/bjophthalmol-2020-318275delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Aims To validate a deep learning (DL) algorithm (DLA) for 360 degrees angle assessment on swept-source optical coherence tomography (SS-OCT) (CASIA SS-1000, Tomey Corporation, Nagoya, Japan). Methods This was a reliability analysis from a cross-sectional study. An independent test set of 39 936 SS-OCT scans from 312 phakic subjects (128 SS-OCT meridional scans per eye) was analysed. Participants above 50 years with no previous history of intraocular surgery were consecutively recruited from glaucoma clinics. Indentation gonioscopy and dark room SS-OCT were performed. Gonioscopic angle closure was defined as non-visibility of the posterior trabecular meshwork in >= 180 degrees of the angle. For each subject, all images were analysed by a DL-based network based on the VGG-16 architecture, for gonioscopic angle-closure detection. Area under receiver operating characteristic curves (AUCs) and other diagnostic performance indicators were calculated for the DLA (index test) against gonioscopy (reference standard). Results Approximately 80% of the participants were Chinese, and more than half were women (57.4%). The prevalence of gonioscopic angle closure in this hospital-based sample was 20.2%. After analysing a total of 39 936 SS-OCT scans, the AUC of the DLA was 0.85 (95% CI:0.80 to 0.90, with sensitivity of 83% and a specificity of 87%) to classify gonioscopic angle closure with the optimal cut-off value of >35% of circumferential angle closure. Conclusions The DLA exhibited good diagnostic performance for detection of gonioscopic angle closure on 360 degrees SS-OCT scans in a glaucoma clinic setting. Such an algorithm, independent of the identification of the scleral spur, may be the foundation for a non-contact, fast and reproducible 'automated gonioscopy' in future.
Keywords:
angle
glaucoma
imaging

Journal

British Journal of Ophthalmology cover
British Journal of Ophthalmology
IF:
3.5
Papers:
1.1W
Citations:
2.4W

Organization

N
Nanyang Technological University
Scholars:
4.9W
Papers: 4.8W
Citations: 8.1W
Singapore National Eye Center cover
Singapore National Eye Center
Scholars:
2.1K
Papers: 1.7K
Citations: 3.4K
N
National University of Singapore
Scholars:
7.5W
Papers: 6.4W
Citations: 11.4W
researcher View more organizations