arrow
Return

Two bit correlation - An adaptive time delay estimation

delete1996-05-01
delete9
PRE
AI
L
Liangmin Wang *
K
K. Kirk Shung
C
Camps, OI
DOI:10.1109/58.489407delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Time delay estimation is a very important operation in ultrasound time-domain flow mapping and correction of phase aberration of an array transducer. As the interest increases in the application of one and a half-dimensional (1.5-D) and two-dimensional (2-D) array transducers to improving image quality and three-dimensional (3-D) imaging [1], [2], the need of simple, fast, and sufficiently accurate algorithms for real-time time delay estimation becomes exceedingly crucial. In this paper, we present an adaptive time-delay estimation algorithm which minimizes the problem of noise sensitivity associated with the one bit correlation [3] while retaining simplicity in implementation. This algorithm converts each sample datum into a two bit representation including the sign of the sample and an adaptively selected threshold. A bit pattern correlation operation is applied to find the time delay between two engaged signals. By using the criterion of misregistration as an indicator, we are able to show that the proposed algorithm is better than one bit correlation in susceptibility to noise level. Analytical results show that the improvement in reducing misregistration of the two bit correlation over its counterpart is consistent over a wide range of noise level. This is achieved by an adaptive adjustment of the threshold to accommodate signal corruption due to noise. The analytical results are corroborated by results from simulating the blood as a random distribution of red blood cells. Finally, we also present a memory-based architecture to implement the two bit correlation algorithm whose computation time does not depend upon the time delay of the signals to be correlated.
Keywords:
FLOWING WHOLE-BLOOD
ULTRASONIC BACKSCATTER
SCATTERING
DEPENDENCE
FREQUENCY
SYSTEMS
ECHOES
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control cover
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
Papers:
6.7K
Citations:
1.4W

Organization

No organization information available
Cited Papers

Cited Papers

errShare
errSave
errShare
errSave
Novel mouse model of indwelling pleural catheter in mice with malignant pleural effusion
err2019-05-28
err0
errOAAI
errChristopher Merrick; Taylor Sherrill; Nikolaos I. Kanellakis; Rachelle Asciak; Georgios T. Stathopoulos; Fabien Maldonado; Najib M. Rahman; Timothy Blackwell; Ioannis Psallidas
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Receptivity to Weight Management Interventions Among Hospitalized Obese Patients
err2013-06-01
err0
PREAI
errChé Matthew Harris; Rebeca Rios; Regina Landis; Waseem Khaliq; Scott Wright
errShare
errSave
Investigating the influence of wall frictions on hopper flows
err2014-11-19
err0
PREAI
errSheng Zhang; Ping Lin; Cang-Long Wang; Yuan Tian; Jiang-Feng Wan; Lei Yang
errShare
errSave
errShare
errSave
errShare
errSave
researcher View more