arrow
Return

United Reference Method for three-dimensional treatment evaluation

delete2018-12-03
delete6
delete
OA
AI
S
Shereef Shahen
M
Manuel O. Lagravère
G
Gennaro Carrino
F
Fady Fahim
R
Reham Abdelsalam
C
Carlos Flores‐Mir
L
Letizia Perillo *
DOI:10.1186/s40510-018-0242-0delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
BackgroundReproducible and descriptive Three-dimensional treatment evaluation can enhance future treatment based on realistic results. So, the purpose of this study was to describe a new method for three-dimensional treatment evaluation showing how to use fully-automated craniofacial superimposition of CBCT records combined with reference system to obtain descriptive and comparable results. This new method was named United Reference Method (URM).MethodsURM is a combination of automated 3D superimposition on anterior cranial base surface anatomy and measurements based on reference system. It was developed to show how to use fully-automated superimposition to obtain descriptive numerical comparable values. The method is based on: one main reference system for both superimposed CBCT records, semi-automation to increase accuracy, all measurements are projections and auxiliary references to aid in landmarks identification and measurements.The method steps can be described following a four-step approach: (1) Superimposition performed through a fully automated, voxel-wise, rigid registration considering only cranial base as a stable structure; (2) Identification of reference landmarks once on the superimposed records for corrected Frankfort Horizontal plane (C-FH) construction and a new semi-automated constructed Sella point to correct Orbital asymmetry; (3) Head orientation of superimposed CBCT images based on the C-FH; (4) Identification of landmarks affected by treatment with the aid of auxiliary reference planes. Evaluation of linear or angular changes derived by projection of same pre- and post-treatment landmarks on the C-FH. Pre- and post-expansion CBCT scans of 20 unilateral cleft lip and palate patients were used to calculate intra and inter-rater reliability. (X, Y and Z) coordinates, mean, standard deviation (SD) and Intra-class Correlation Coefficient (ICC) were calculated.ResultsThe proposed coordinates for C-FH construction showed ICC0.998 and SD ranging from 0.064 to 0.242mm. On the other hand, excluded coordinates due to expected natural craniofacial asymmetry had the lowest reliability ICC 0.742 and SD dramatically increased up to 1.112mm.ConclusionURM showed adequate reliability so it can be used to produce three-dimensional descriptive data of craniofacial structural changes.
Keywords:
Three-dimensional treatment evaluation
Descriptive three-dimensional superimposition
Three-dimensional reference system
Semi-automated landmarks
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Progress in Orthodontics cover
Progress in Orthodontics
IF:
5
Papers:
568
Citations:
2.4K

Organization

E
egyptian knowledge bank (ekb)
Scholars:
11.6W
Papers: 9.3W
Citations: 84
U
university of alberta
Scholars:
5.1W
Papers: 4.9W
Citations: 65
C
Cairo University
Scholars:
1.4W
Papers: 1.1W
Citations: 1.7W
U
universita della campania vanvitelli
Scholars:
1.8W
Papers: 1.4W
Citations: 13
researcher View more organizations
Cited Papers

Cited Papers

Multimodality image registration by maximization of mutual information
err1997-04-01
err4.1K
errOAAI
errMaes, F; Collignon, A; Vandermeulen, D; Marchal, G; Suetens, P
errShare
errSave
CBCT of skeletal changes following rapid maxillary expansion to increase arch-length with a development-dependent bonded or banded appliance
err2013-03-14
err39
errOAAI
errKanomi, Ryuzo; Deguchi, Toru; Kakuno, Eriko; Takano-Yamamoto, Teruko; Roberts, W. Eugene
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
An Introduction to Petrology
err1910-05-01
err0
errOAAI
errG. A. J. C.
errShare
errSave
researcher View more