1
Return

Video-Oculography-Based Detection of Skew Deviation in Patients Experiencing Dizziness in the Outpatient Setting: A Prospective Diagnostic Accuracy Study

delete2026-08-12
delete0
delete
OA
AI
T
Tzu-Pu Chang
H
Hong-Hua Lin
A
Anand K. Bery *
DOI:10.3390/brainsci16080850delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Background: Skew deviation, a vertical ocular misalignment caused by brainstem or cerebellar dysfunction, is strongly associated with central lesions in acute vestibular syndrome but has not been systematically studied in outpatient settings. This clinic-based study evaluated the prevalence of video-oculography (VOG)-guided skew deviation, its diagnostic value for posterior fossa lesions, and the accuracy of an automated VOG algorithm for skew detection. Methods: Consecutive dizzy patients attending a neurology clinic over 18 months underwent a VOG-guided alternate cover test. Vertical eye deviation was automatically quantified by the VOG software and validated by expert review of VOG traces and/or videos (expert review constituted the gold standard in this study). We analyzed the prevalence and diagnostic performance of skew deviation for posterior fossa lesions. Receiver operating characteristic analysis and area under the curve (AUC) were used to evaluate the automated algorithm. Results: Among 226 dizzy patients, skew deviation was identified in 5.3% (95% CI 3.1–9.1%). For predicting posterior fossa lesions, skew deviation showed a sensitivity of 23.7% (95% CI 13.0–39.2%), specificity of 98.4% (95% CI 95.4–99.5%), positive predictive value of 75.0% (95% CI 46.8–91.1%), and negative predictive value of 86.4% (95% CI 81.2–90.4%). The automated VOG algorithm demonstrated promising performance for detecting skew deviation, with AUCs of 0.88 for the right eye (95% CI 0.77–0.99) and 0.94 for the left eye (95% CI 0.91–0.97). Conclusions: Skew deviation is uncommon in outpatient dizzy patients, but its high positive predictive value supports its utility as an adjunctive predictor of posterior fossa lesions. Although the automated VOG algorithm showed promising performance, expert review of traces and/or video remains necessary because false-positive results may occur.
Keywords:
skew deviation
dizziness
vertigo
video-oculography
central vestibulopathy
diagnosis

Journal

B
Brain Sciences
IF:
2.8
Papers:
1.2K
Citations:
0

Organization

T
Taichung Tzu Chi Hospital
Scholars:
238
Papers: 183
Citations: 3
M
Massachusetts Eye and Ear Infirmary
Scholars:
32
Papers: 18
Citations: 1
B
Buddhist Tzu Chi Medical Foundation
Scholars:
247
Papers: 125
Citations: 58
Cited Papers

Cited Papers

Citing Papers

Citing Papers