arrow
Back
J

Johan Gustafsson

Lund University

19H-index
62Paper Count
1.2KCitation Count
Published Papers 37
Publication Date
Evaluation of modified window-based scatter compensation in quantitative 177Lu-SPECT for a ring-configured CZT SPECT-CT
err2026-06-14
err0
errOAAI
errIrma Ceric Andelius; Anna Stenvall; Elias Nilsson; Erik Larsson; Johan Gustafsson
errShare
errSave
Improved patient models for simulation of clinically realistic 68Ga-SSTR PET and 177Lu-PRRT SPECT studies
err2026-05-25
err0
errOAAI
errJohan Gustafsson; Philip Kalaitzidis; Selma Curkic Kapidzic; Michael Ljungberg; Katarina Sjögreen Gleisner
errShare
errSave
[177Lu]Lu-DOTA-TATE tumour and organ time-activity curves: prediction from a single-time-point [68Ga]Ga-DOTA-TATE PET/CT measurement
err2026-01-16
err0
errOAAI
errValentina Vasić; Johan Gustafsson; Elham Yousefzadeh-Nowshahr; Ambros J. Beer; Katarina Sjögreen Gleisner; Gerhard Glatting
errShare
errSave
MIRD Pamphlet No. 33: MIRDpvc-A Software Tool for Recovery Coefficient-Based Partial-Volume Correction
err2025-11-01
err0
PREAI
errMarquis, Harry; Gustafsson, Johan; Schmidtlein, C. Ross; De Nijs, Robin; Gabin, Pablo Mingueznguez; Kayal, Gunjan; Ramos, Juan C. Ocampo; Carter, Lukas M.; Bailey, Dale L.; Kesner, Adam L.
errShare
errSave
A validation protocol for 177Lu-SPECT image quantification as a basis for multi-centre kidney dosimetry
err2025-05-19
err0
PREAI
errJessen, Lovisa; Kapidzic, Selma Curkic; Gustafsson, Johan; Larsson, Erik; Ljungberg, Michael; Sandstrom, Mattias; Dalmo, Johanna; Hagmarker, Linn; Hindorf, Cecilia; Taprogge, Jan; Gear, Jonathan; Flux, Glenn; Gleisner, Katarina Sjogreen
errShare
errSave
errShare
errSave
Bias and precision of SPECT-based 177Lu activity-concentration estimation using a ring-configured solid-state versus a dual-headed anger system
err2024-11-04
err1
errOAAI
errStenvall, Anna; Ceric Andelius, Irma; Nilsson, Elias; Lindvall, Albin; Larsson, Erik; Gustafsson, Johan
errShare
errSave
Pareto optimization of SPECT acquisition and reconstruction settings for 177Lu activity quantification
err2024-07-15
err2
errOAAI
errGustafsson, Johan; Larsson, Erik; Ljungberg, Michael; Gleisner, Katarina Sjoegreen
errShare
errSave
Position dependence of recovery coefficients in 177Lu-SPECT/CT reconstructions - phantom simulations and measurements
err2024-06-28
err4
errOAAI
errLeube, Julian; Claeys, Wies; Gustafsson, Johan; Salas-Ramirez, Maikol; Lassmann, Michael; Koole, Michel; Tran-Gia, Johannes
errShare
errSave
Relationship Between Absorbed Dose and Response in Neuroendocrine Tumors Treated with [ 177 Lu]Lu-DOTATATE
err2024-05-09
err4
PREAI
errWarfvinge, Carl Fredrik; Gustafsson, Johan; Roth, Daniel; Tennvall, Jan; Svensson, Johanna; Bernhardt, Peter; Akesson, Anna; Wieslander, Elinore; Sundlov, Anna; Gleisner, Katarina Sjogreen
errShare
errSave
A Deep-Learning-Based Partial-Volume Correction Method for Quantitative 177Lu SPECT/CT Imaging
err2024-04-18
err3
PREAI
errLeube, Julian; Gustafsson, Johan; Lassmann, Michael; Salas-Ramirez, Maikol; Tran-Gia, Johannes
errShare
errSave
Kidney dosimetry in [ 177 Lu]Lu-DOTA-TATE therapy based on multiple small VOIs
err2024-04-01
err0
PREAI
errKapidzic, Selma Curkic; Gustafsson, Johan; Larsson, Erik; Jessen, Lovisa; Gleisner, Katarina Sjogreen
errShare
errSave
A PBPK model for PRRT with [177Lu]Lu-DOTA-TATE: Comparison of model implementations in SAAM II and MATLAB/SimBiology
err2024-03-01
err4
errOAAI
errVasic, Valentina; Gustafsson, Johan; Nowshahr, Elham Yousefzadeh; Stenvall, Anna; Beer, Ambros J.; Glatting, Gerhard; Gleisner, Katarina Sjogreen
errShare
errSave
3D printed non-uniform anthropomorphic phantoms for quantitative SPECT
err2024-01-22
err0
errOAAI
errJessen, Lovisa; Gustafsson, Johan; Ljungberg, Michael; Curkic-Kapidzic, Selma; Imsirovic, Muris; Sjogreen-Gleisner, Katarina
errShare
errSave
Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden
err2023-12-01
err1
errOAAI
errHindorf, Cecilia; Jessen, Lovisa; Kapidzic, Selma Curkic; Blakkisrud, Johan; Dalmo, Johanna; Engelsen, Ola; Gustafsson, Johan; Sandstrom, Mattias; Saeterstol, Jostein; Gleisner, Katarina Sjogreen
errShare
errSave
Monte Carlo investigation of PET [68Ga]Ga-DOTA-TOC activity-administration protocols for consistent image quality
errHELIYON
IF3.6
err2023-09-01
err0
errOAAI
errKalaitzidis, Philip; Gustafsson, Johan; Hindorf, Cecilia; Ljungberg, Michael
errShare
errSave
Activity recovery for differently shaped objects in quantitative SPECT
err2023-06-16
err4
PREAI
errMinguez Gabina, Pablo; Monserrat Fuertes, Teresa; Jauregui, Ines; del Amo, Cristina; Ortiz de Zarate, Emilia Rodeno; Gustafsson, Johan
errShare
errSave
Averaging of absorbed doses: How matter matters
err2023-06-05
err1
errOAAI
errGustafsson, Johan; Ljungberg, Michael; Carlsson, Gudrun Alm; Larsson, Erik; Warfvinge, Carl Fredrik; Asp, Pernilla; Gleisner, Katarina Sjogreen
errShare
errSave