A universal parameterized gradient-based method for photon beam field size determination

delete2017-10-13
delete6
PRE
AI
S
S Lebron
G
Guanghua Yan
J
Jonathan Li
B
Bo Lü
C
Chihray Liu *
DOI:10.1002/mp.12573delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
PurposeTo propose a universal, parameterized gradient-based method (PGM) for radiation field size determination. MethodsThe PGM locates the beam profile's edge by parameterizing its penumbra region with a modified sigmoid function where the inflection point can be determined in a closed form. The parametrization was validated with filter-flattened (FF), flattening-filter-free (FFF) and wedged profiles measured on two Elekta linac models (Synergy and Versa HD). Gamma analysis with the delta dose function set to zero was used to quantitatively assess the parameterization accuracy. Field sizes of FF beams were calculated with the PGM and the full width at half maximum (FWHM) methods for comparison. To assess the consistency of the PGM and the FWHM method with geometric scaling across different depths, the calculated field size at a reference depth was scaled to other depths and compared with the field sizes calculated from the measured profiles. The method was also validated against a maximum-slope method (MSM) with wedge and FFF profiles. We also evaluated the robustness of the three methods with respect to measurement noise, varying scanning step sizes, detector characteristics, and beam energy/modality. ResultsSmall distance-to-agreement (0.020.02mm) between the measured and parameterized penumbra region was observed for all profiles. The differences between the field sizes calculated with the FWHM method and the PGM were consistent (0.9 +/- 0.3mm), with the FWHM method yielding larger values. With geometrical scaling, the PGM and the FWHM method produced maximum differences of 0.26 and 1.16mm, respectively. For wedge and FFF beams, the mean differences relative to FF fields were 0.15 +/- 0.09mm and 0.57 +/- 0.91mm for the PGM and the MSM, respectively. The PGM was also found to produce more consistent results than the FWHM method and the MSM when measurement noise, scanning step size, detector characteristics, and beam energy/modality changed. ConclusionThe proposed PGM is universally applicable to all beam modalities (FF, wedge and FFF) for accurate field size determination. Compared to the FWHM and the MSM, it is more robust to variations in measurement condition and detection system.
Keyword:
field size
linac
parameterization
quality assurance
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

State University System of Florida 封面图
State University System of Florida
学者数:
12.8W
论文数: 10.9W
被引数: 130
引用论文

引用论文

Parameterization of photon beam dosimetry for a linear accelerator直线加速器光子束剂量的参数化
err2016-01-14
err8
PREAI
errLebron, Sharon; Lu, Bo; Yan, Guanghua; Kahler, Darren; Li, Jonathan G.; Barraclough, Brendan; Liu, Chihray
err分享
err收藏
Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy
err2012-10-03
err75
PREAI
errFogliata, A.; Garcia, R.; Knoos, T.; Nicolini, G.; Clivio, A.; Vanetti, E.; Khamphan, C.; Cozzi, L.
err分享
err收藏
A technique for the quantitative evaluation of dose distributions
err1998-05-01
err2.6K
errOAAI
errLow, DA; Harms, WB; Mutic, S; Purdy, JA
err分享
err收藏
Small fields:: Nonequilibrium radiation dosimetry小场:: 非平衡辐射剂量学
err2007-12-20
err616
PREAI
errDas, Indra J.; Ding, George X.; Ahnesjo, Anders
err分享
err收藏
Properties of unflattened photon beams shaped by a multileaf collimator
err2006-05-18
err127
PREAI
errPonisch, Falk; Titt, Uwe; Vassiliev, Oleg N.; Kry, Stephen F.; Mohan, Radhe
err分享
err收藏
没有更多内容