arrow
返回

Analysis types and quantification methods applied in UHPLC-MS metabolomics research: a tutorial

delete2024-08-07
delete5
delete
OA
AI
R
Richard D. Beger
R
Royston Goodacre
C
Christina M. Jones
K
Katrice A. Lippa
O
Oleg A. Mayboroda
D
Donna O’Neill
L
Lukáš Najdekr
I
Ioanna Ntai
I
Ian D. Wilson
W
Warwick B. Dunn *
DOI:10.1007/s11306-024-02155-6delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
BackgroundDifferent types of analytical methods, with different characteristics, are applied in metabolomics and lipidomics research and include untargeted, targeted and semi-targeted methods. Ultra High Performance Liquid Chromatography-Mass Spectrometry is one of the most frequently applied measurement instruments in metabolomics because of its ability to detect a large number of water-soluble and lipid metabolites over a wide range of concentrations in short analysis times. Methods applied for the detection and quantification of metabolites differ and can either report a (normalised) peak area or an absolute concentration.Aim of reviewIn this tutorial we aim to (1) define similarities and differences between different analytical approaches applied in metabolomics and (2) define how amounts or absolute concentrations of endogenous metabolites can be determined together with the advantages and limitations of each approach in relation to the accuracy and precision when concentrations are reported.Key scientific concepts of reviewThe pre-analysis knowledge of metabolites to be targeted, the requirement for (normalised) peak responses or absolute concentrations to be reported and the number of metabolites to be reported define whether an untargeted, targeted or semi-targeted method is applied. Fully untargeted methods can only provide (normalised) peak responses and fold changes which can be reported even when the structural identity of the metabolite is not known. Targeted methods, where the analytes are known prior to the analysis, can also report fold changes. Semi-targeted methods apply a mix of characteristics of both untargeted and targeted assays. For the reporting of absolute concentrations of metabolites, the analytes are not only predefined but optimized analytical methods should be developed and validated for each analyte so that the accuracy and precision of concentration data collected for biological samples can be reported as fit for purpose and be reviewed by the scientific community.
Keyword:
Metabolomics
UHPLC-MS
Quantification
Untargeted
Semi-targeted
Targeted
Validation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Metabolomics 封面图
Metabolomics
IF:
3.3
论文数:
2.4K
被引数:
6.3K

机构

U
University of Birmingham
学者数:
4.1W
论文数: 3.8W
被引数: 5.0W
U
us food & drug administration (fda)
学者数:
1.4W
论文数: 9.3K
被引数: 3
L
leiden university - excl lumc
学者数:
3.5W
论文数: 2.9W
被引数: 46
U
University of Liverpool
学者数:
2.8W
论文数: 2.5W
被引数: 3.5W
L
Leiden University
学者数:
4.0W
论文数: 3.3W
被引数: 3.8W
N
national institute of standards & technology (nist) - usa
学者数:
9.7K
论文数: 9.0K
被引数: 4
学者 查看更多机构
引用论文

引用论文

Anomalous dynamics of translocation
err2001-12-14
err0
errOAAI
errJeffrey Chuang; Yacov Kantor; Mehran Kardar
err分享
err收藏
Advances in high throughput LC/MS based metabolomics: A review基于高通量LC/MS的代谢组学研究进展
err2023-03-01
err27
errOAAI
errPlumb, Robert S.; Gethings, Lee A.; Rainville, Paul D.; Isaac, Giorgis; Trengove, Robert; King, Adam M.; Wilson, lan D.
err分享
err收藏
High-Resolution, Accurate-Mass (HRAM) Mass Spectrometry Urine Steroid Profiling in the Diagnosis of Adrenal Disorders
err2017-12-01
err75
errOAAI
errHines, Jolaine M.; Bancos, Irina; Bancos, Cristian; Singh, Raman D.; Avula, Aditya V.; Young, William F.; Grebe, Stefan K.; Singh, Ravinder J.
err分享
err收藏
err分享
err收藏
Procedures for large-scale metabolic profiling of serum and plasma using gas chromatography and liquid chromatography coupled to mass spectrometry使用气相色谱和液相色谱与质谱联用对血清和血浆进行大规模代谢分析的程序
err2011-06-30
err2.4K
PREAI
errDunn, Warwick B.; Broadhurst, David; Begley, Paul; Zelena, Eva; Francis-McIntyre, Sue; Anderson, Nadine; Brown, Marie; Knowles, Joshau D.; Halsall, Antony; Haselden, John N.; Nicholls, Andrew W.; Wilson, Ian D.; Kell, Douglas B.; Goodacre, Royston
err分享
err收藏
Guidelines and considerations for the use of system suitability and quality control samples in mass spectrometry assays applied in untargeted clinical metabolomic studies
err2018-05-18
err600
errOAAI
errBroadhurst, David; Goodacre, Royston; Reinke, Stacey N.; Kuligowski, Julia; Wilson, Ian D.; Lewis, Matthew R.; Dunn, Warwick B.
err分享
err收藏
Current developments in LC-MS for pharmaceutical analysis
errANALYST
IF3.3
err2020-01-01
err177
errOAAI
errBeccaria, Marco; Cabooter, Deirdre
err分享
err收藏
学者 查看更多内容