arrow
返回

Axial accuracy in localization microscopy with 3D point spread function engineering

delete2022-07-18
delete6
delete
OA
AI
M
Marijn Siemons
L
Lukas C. Kapitein
S
Sjoerd Stallinga *
DOI:10.1364/OE.461750delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Single-molecule localization microscopy has developed into a widely used technique to overcome the diffraction limit and enables 3D localization of single-emitters with manometer precision. A widely used method to enable 3D encoding is to use a cylindrical lens or a phase mask to engineer the point spread function (PSF). The performance of these PSFs is often assessed by comparing the precision they achieve, ignoring accuracy. Nonetheless, accurate localization is required in many applications, such as multi-plane imaging, measuring and modelling of physical processes based on volumetric data, and 3D particle averaging. However, there are PSF model mismatches in the localization schemes due to how reference PSFs are obtained, look-up-tables are created, or spots are fitted. Currently there is little insight in how these model mismatches give rise to systematic axial localization errors, how large these errors are, and how to mitigate them. In this theoretical and simulation work we use a vector PSF model, which incorporates super-critical angle fluorescence (SAF) and the appropriate aplanatic correction factor, to analyze the errors in z-localization. We introduce theory for defining the focal plane in SAF conditions and analyze the predicted axial errors for an astigmatic PSF, double-helix PSF, and saddle-point PSF. These simulations indicate that the absolute axial biases can be as large as 140 nm, 250 nm, and 120 nm for the astigmatic, saddle-point, and double-helix PSF respectively, with relative errors of more than 50%. Finally, we discuss potential experimental methods to verify these findings and propose a workflow to mitigate these effects. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
Keyword:
CALIBRATION

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

U
Utrecht University
学者数:
6.0W
论文数: 5.1W
被引数: 5.8W
D
Delft University of Technology
学者数:
2.6W
论文数: 2.5W
被引数: 3.8W
引用论文

引用论文

Aberration-accounting calibration for 3D single-molecule localization microscopy
err2018-01-03
err32
errOAAI
errCabriel, Clement; Bourg, Nicolas; Dupuis, Guillaume; Leveque-Fort, Sandrine
err分享
err收藏
Combining 3D single molecule localization strategies for reproducible bioimaging
err2019-04-30
err32
errOAAI
errCabriel, Clement; Bourg, Nicolas; Jouchet, Pierre; Dupuis, Guillaume; Leterrier, Christophe; Baron, Aurelie; Badet-Denisot, Marie-Ange; Vauzeilles, Boris; Fort, Emmanuel; Leveque-Fort, Sandrine
err分享
err收藏
Axial super-localisation using rotating point spread functions shaped by polarisation-dependent phase modulation
err2014-02-13
err48
errOAAI
errRoider, Clemens; Jesacher, Alexander; Bernet, Stefan; Ritsch-Marte, Monika
err分享
err收藏
Socioeconomic Factors, Hazardous Alcohol Consumption, and Smoking in Patients With Minor Trauma in an Inner-City Emergency Department
err2010-11-01
err0
PREAI
errBruno Neuner; Peter Miller; Kang Kandy Wang; Edith Weiss-Gerlach; Tim Neumann; Helge Schoenfeld; Norbert Haas; Joachim M. Mueller; Klaus Dieter Wernecke; Karl Mann; Sven Andréasson; Claudia Spies
err分享
err收藏
ZOLA-3D allows flexible 3D localization microscopy over an adjustable axial range
err2018-06-19
err83
errOAAI
errAristov, Andrey; Lelandais, Benoit; Rensen, Elena; Zimmer, Christophe
err分享
err收藏
err分享
err收藏
Robust adaptive optics for localization microscopy deep in complex tissue
err2021-06-07
err26
errOAAI
errSiemons, Marijn E.; Hanemaaijer, Naomi A. K.; Kole, Maarten H. P.; Kapitein, Lukas C.
err分享
err收藏
学者 查看更多内容