arrow
返回

Dynamic PET reconstruction using wavelet regularization with adapted basis functions

delete2008-07-01
delete59
delete
OA
AI
J
Jeroen Verhaeghe *
D
Dimitri Van De Ville
I
Ildar Khalidov
Y
Yves D’Asseler
I
Ignace Lemahieu
M
Michaël Unser
DOI:10.1109/TMI.2008.923698delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1)-regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algorithm developed by Daubechies et al, 2004. In this paper, we apply this technique and extend it for the reconstruction of dynamic (spatio-temporal) PET data. Moreover, instead of using classical wavelets in the temporal dimension, we introduce exponential-spline wavelets (E-spline wavelets) that are specially tailored to model time activity curves (TACs) in PET. We show that the exponential-spline wavelets naturally arise from the compartmental description of the dynamics of the tracer distribution. We address the issue of the selection of the optimal E-spline parameters (poles and zeros) and we investigate their effect on reconstruction quality. We demonstrate the usefulness of spatio-temporal regularization and the superior performance of E-spline wavelets over conventional Battle-Lemarie wavelets in a series of experiments: the 1-D fitting of TACs, and the tomographic reconstruction of both simulated and clinical data. We find that the E-spline wavelets outperform the conventional wavelets in terms of the reconstructed signal-to-noise ratio (SNR) and the sparsity of the wavelet coefficients. Based on our simulations, we conclude that replacing the conventional wavelets with E-spline wavelets leads to equal reconstruction quality for a 40% reduction of detected coincidences, meaning an improved image quality for the same number of counts or equivalently a reduced exposure to the patient for the same image quality.
Keyword:
differential system
E-spline wavelets
l(1)-regularization
spatio-temporal positron emission tomography (PET) reconstruction
time-activity-curves

期刊

IEEE Transactions on Medical Imaging 封面图
IEEE Transactions on Medical Imaging
IF:
9.8
论文数:
6.2K
被引数:
3.7W

机构

G
Ghent University
学者数:
5.2W
论文数: 4.5W
被引数: 5.5W
E
Ecole Polytechnique Federale de Lausanne
学者数:
1.7W
论文数: 1.3W
被引数: 25
S
swiss federal institutes of technology domain
学者数:
9.0W
论文数: 8.0W
被引数: 163
学者 查看更多机构
引用论文

引用论文

err分享
err收藏
Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM
err2006-10-06
err87
PREAI
errReader, Andrew J.; Sureau, Florent C.; Comtat, Claude; Trebossen, Regine; Buvat, Irene
err分享
err收藏
電気化学キャパシタ
err2000-12-05
err0
errOAAI
errTakeshi MORIMOTO
err分享
err收藏
Nectar trichome structure of aquatic bladderworts from the section Utricularia (Lentibulariaceae) with observation of flower visitors and pollinators
err2018-02-05
err0
errOAAI
errBartosz J. Płachno; Małgorzata Stpiczyńska; Lubomír Adamec; Vitor Fernandes Oliveira Miranda; Piotr Świątek
err分享
err收藏
学者 查看更多内容