arrow
返回

Localization events-based sample drift correction for localization microscopy with redundant cross-correlation algorithm

delete2014-06-20
delete135
delete
OA
AI
Y
Yina Wang
J
Joerg Schnitzbauer
Z
Zhe Hu
李雪明 (Xueming Li)
Y
Yifan Cheng
黄振立 封面图
黄振立 (Zhen‐Li Huang)
B
Bo Huang *
DOI:10.1364/OE.22.015982delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Highly accurate sample drift correction is essential in super-resolution localization microscopy to guarantee a high spatial resolution, especially when the technique is used to visualize small cell organelle. Here we present a localization events-based drift correction method using a redundant cross-correlation algorithm originally developed to correct beam-induced motion in cryo-electron microscopy. With simulated, synthesized as well as experimental data, we have demonstrated its superior precision compared to previously published localization events-based drift correction methods. The major advantage of this method is the robustness when the number of localization events is low, either because a short correction time step is required or because the imaged structure is small and sparse. This method has allowed us to improve the effective resolution when imaging Golgi apparatus in mammalian cells. (C) 2014 Optical Society of America
Keyword:
RESOLUTION
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

U
university of california san francisco
学者数:
5.3W
论文数: 4.0W
被引数: 67
University of California System 封面图
University of California System
学者数:
37.5W
论文数: 33.7W
被引数: 6.6K
引用论文

引用论文

Fluorescence nanoscopy in whole cells by asynchronous localization of photoswitching emitters
err2007-11-01
err252
errOAAI
errEgner, Alexander; Geisler, Claudia; Von Middendorff, Claas; Bock, Hannes; Wenzel, Dirk; Medda, Rebecca; Andresen, Martin; Stiel, Andre C.; Jakobs, Stefan; Eggeling, Christian; Schoenle, Andreas; Hell, Stefan W.
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM电子计数和束诱导的运动校正可实现近原子分辨率的单粒子cryo-em
err2013-05-05
err1.6K
errOAAI
errLi, Xueming; Mooney, Paul; Zheng, Shawn; Booth, Christopher R.; Braunfeld, Michael B.; Gubbens, Sander; Agard, David A.; Cheng, Yifan
err分享
err收藏
err分享
err收藏
Using fixed fiduciary markers for stage drift correction
err2012-05-14
err89
errOAAI
errLee, Sang Hak; Baday, Murat; Tjioe, Marco; Simonson, Paul D.; Zhang, Ruobing; Cai, En; Selvin, Paul R.
err分享
err收藏
err分享
err收藏
Ultra-fast, high-precision image analysis for localization-based super resolution microscopy
err2010-05-20
err69
errOAAI
errQuan, Tingwei; Li, Pengcheng; Long, Fan; Zeng, Shaoqun; Luo, Qingming; Hedde, Per Niklas; Nienhaus, Gerd Ulrich; Huang, Zhen-Li
err分享
err收藏
We have the technology我们有技术
err2017-10-12
err0
errOAAI
errKatherine Bourzac
err分享
err收藏
学者 查看更多内容