Self-Calibrated Ion-Selective Electrodes
DOI:10.1021/acs.analchem.3c02135.png)
摘要
En 中文
Ion-selective electrode (ISE) potentiometry is reliableonly ifon-site calibration using a standard solution is performed beforeion measurements. The complex device and operation required for calibrationhinder the implementation of ISEs in decentralized sensing. Reportedherein is a new type of ISE that is calibrated by a built-in componentof the sensor without requiring any fluid handling processes. Theindicator and reference electrodes are connected by a thin ionic conductorsuch as an aqueous phase containing the measuring ions in a capillarytube. This connection establishes a baseline electromotive force (EMF)that incorporates phase boundary potentials across multiple interfacesof the electrochemical cell and serves as a one-point calibration.Unlike conventional ISEs that rely on one EMF reading for each measurement,the proposed sensor utilizes a sample-induced EMF change relativeto the baseline for each ion measurement. The variability in relativeEMF is found to be <2.0 mV for multiple full potentiometric sensorsconsisting of plasticizer-based K+ ISEs and hydrogel-basedAg/AgCl reference electrodes. This value is significantly smallerthan the variability of absolute EMF readouts in similar sensors withoutthe self-calibration design. Moreover, when the ion-conducting calibrationbridge has a low concentration of primary ions, low ion mobility,and/or a small contact area with the indicator and reference phases,it does not compromise the Nernstian response slope toward the analyteions in the sample and therefore does not need to be removed for sampletesting. The accuracy of the single-use self-calibrated K+ sensor in testing undiluted human blood samples is validated usinga commercial blood gas analyzer as the reference method. Althoughthis study focuses on disposable sensors consisting of tubes, thefluidics-free self-calibration strategy may be adapted to other sensorconfigurations such as planar sensors.
Keyword:
LOWER DETECTION LIMIT
SOLID-CONTACT
CONDUCTING POLYMER
MEMBRANE
HYPERKALEMIA
期刊
IF:
6.7
论文数:
4.7W
被引数:
15.9W
机构
引用论文
TEMPO-Functionalized Carbon Nanotubes for Solid-Contact Ion-Selective Electrodes with Largely Improved Potential Reproducibility and Stability
ANALYTICAL CHEMISTRY
IF6.7
Body-Interfaced Chemical Sensors for Noninvasive Monitoring and Analysis of Biofluids
TRENDS IN CHEMISTRY
IF13.6
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
ANALYTICAL CHEMISTRY
IF6.7
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis完全集成的可穿戴传感器阵列,用于多路复用原位汗液分析
Nature
IF0
Calibration-free Solid-State Ion-Selective Electrode Based on a Polarized PEDOT/PEDOT-S-Doped Copolymer as Back Contact基于极化PEDOT/pedot-s掺杂共聚物作为背接触的免校准固态离子选择电极
ANALYTICAL CHEMISTRY
IF6.7
Rational design of all-solid-state ion-selective electrodes and reference electrodes全固态离子选择电极和参比电极的合理设计
Production of Interspecific Hybrids between Gossypium hirsutum and Jassid Resistant Wild Species G. raimondii and G. armourianum
CYTOLOGIA
IF0
Accessing analytes in biofluids for peripheral biochemical monitoring访问生物流体中的分析物以进行外围生化监测
NATURE BIOTECHNOLOGY
IF41.7