Self-Calibrated Ion-Selective Electrodes

delete2023-07-13
delete5
PRE
AI
N
Nafesa Adil
R
Renjie Wang
王学伟 封面图
王学伟 (Xuewei Wang) *
DOI:10.1021/acs.analchem.3c02135delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Ion-selective electrode (ISE) potentiometry is reliableonly ifon-site calibration using a standard solution is performed beforeion measurements. The complex device and operation required for calibrationhinder the implementation of ISEs in decentralized sensing. Reportedherein is a new type of ISE that is calibrated by a built-in componentof the sensor without requiring any fluid handling processes. Theindicator and reference electrodes are connected by a thin ionic conductorsuch as an aqueous phase containing the measuring ions in a capillarytube. This connection establishes a baseline electromotive force (EMF)that incorporates phase boundary potentials across multiple interfacesof the electrochemical cell and serves as a one-point calibration.Unlike conventional ISEs that rely on one EMF reading for each measurement,the proposed sensor utilizes a sample-induced EMF change relativeto the baseline for each ion measurement. The variability in relativeEMF is found to be <2.0 mV for multiple full potentiometric sensorsconsisting of plasticizer-based K+ ISEs and hydrogel-basedAg/AgCl reference electrodes. This value is significantly smallerthan the variability of absolute EMF readouts in similar sensors withoutthe self-calibration design. Moreover, when the ion-conducting calibrationbridge has a low concentration of primary ions, low ion mobility,and/or a small contact area with the indicator and reference phases,it does not compromise the Nernstian response slope toward the analyteions in the sample and therefore does not need to be removed for sampletesting. The accuracy of the single-use self-calibrated K+ sensor in testing undiluted human blood samples is validated usinga commercial blood gas analyzer as the reference method. Althoughthis study focuses on disposable sensors consisting of tubes, thefluidics-free self-calibration strategy may be adapted to other sensorconfigurations such as planar sensors.
Keyword:
LOWER DETECTION LIMIT
SOLID-CONTACT
CONDUCTING POLYMER
MEMBRANE
HYPERKALEMIA

期刊

Analytical Chemistry 封面图
Analytical Chemistry
IF:
6.7
论文数:
4.7W
被引数:
15.9W

机构

V
Virginia Commonwealth University
学者数:
2.2W
论文数: 1.8W
被引数: 1.9W
引用论文

引用论文

Body-Interfaced Chemical Sensors for Noninvasive Monitoring and Analysis of Biofluids
err2019-09-01
err73
PREAI
errZhao, Jie; Guo, Hexia; Li, Jinghua; Bandodkar, Amay J.; Rogers, John A.
err分享
err收藏
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
err2017-02-27
err66
PREAI
errGuzinski, Marcin; Jarvis, Jennifer M.; Perez, Febo; Pendley, Bradford D.; Lindner, Erno; De Marco, Roland; Crespo, Gaston A.; Acres, Robert G.; Walker, Raymart; Bishop, Josiah
err分享
err收藏
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis完全集成的可穿戴传感器阵列,用于多路复用原位汗液分析
err2016-01-27
err0
errOAAI
errWei Gao; Sam Emaminejad; Hnin Yin Yin Nyein; Samyuktha Challa; Kevin Chen; Austin Peck; Hossain M. Fahad; Hiroki Ota; Hiroshi Shiraki; Daisuke Kiriya; Der-Hsien Lien; George A. Brooks; Ronald W. Davis; Ali Javey
err分享
err收藏
Inner membrane protease I, an enzyme mediating intramitochondrial protein sorting in yeast.
err1991-02-01
err0
errOAAI
errA. Schneider; M. Behrens; P. Scherer; E. Pratje; G. Michaelis; G. Schatz
err分享
err收藏
Accessing analytes in biofluids for peripheral biochemical monitoring访问生物流体中的分析物以进行外围生化监测
err2019-02-25
err462
PREAI
errHeikenfeld, Jason; Jajack, Andrew; Feldman, Benjamin; Granger, Steve W.; Gaitonde, Supriya; Begtrup, Gavi; Katchman, Benjamin A.
err分享
err收藏
Antihypertensive Medications and the Prevalence of Hyperkalemia in a Large Health System
err2016-06-01
err96
errOAAI
errChang, Alex R.; Sang, Yingying; Leddy, Julia; Yahya, Taher; Kirchner, H. Lester; Inker, Lesley A.; Matsushita, Kunihiro; Ballew, Shoshana H.; Coresh, Josef; Grams, Morgan E.
err分享
err收藏
学者 查看更多内容