arrow
返回

Successive projections algorithm combined with uninformative variable elimination for spectral variable selection

delete2008-04-01
delete225
PRE
AI
S
Shengfeng Ye
D
Dong Wang
S
Shungeng Min *
DOI:10.1016/j.chemolab.2007.11.005delete
delete原文链接
delete分享
delete收藏
摘要

摘要

En 中文
The UVE - SPA method, successive projections algorithm (SPA) combined with uninformative variable elimination (UVE) is proposed as a novel variable selection approach for multivariate calibration. UVE is used to select informative variables, and SPA is followed to select variables with minimum redundant information from the informative variables. The proposed method was applied to near-infrared (NIR) reflectance data for analysis of nicotine in tobacco lamina and NIR transmission data for active pharmaceutical ingredient (API) in single tablet. On the aspect of elimination of uninformative variables, the effect of UVE using first derivative spectra was better than that of using raw spectra. In terms of variable selection, fewer variables with better performance were selected by UVE - SPA method than by direct SPA method. For NIR spectral analysis of nicotine in tobacco lamina, the number of variables selected from 3001 spectral variables reduced from 48 by direct SPA to 35 by UVE - SPA, and the root mean squared error of prediction set (RMSEP) of the corresponding MLR models decreased from 0.174 (%, mg/mg) to 0.160. For NIR spectral analysis of API in each tablet, the number of variables selected from 650 spectral variables reduced from 46 by direct SPA to 17 by UVE - SPA, and RMSEP of the corresponding multiple linear regression (MLR) models decreased from 0.842 (%, mg/mg) to 0.473. MLR model using variables selected by UVE - SPA had better prediction performance than full-spectrum partial least-squares (PLS) model, and comparable to PLS model of UVE. (c) 2007 Elsevier B.V. All rights reserved.
Keyword:
successive projections algorithm
uninformative variable elimination
variable selection
near-infrared spectroscopy
multivariate calibration
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Chemometrics and Intelligent Laboratory Systems 封面图
Chemometrics and Intelligent Laboratory Systems
IF:
3.8
论文数:
4.6K
被引数:
1.2W

机构

C
china agricultural university
学者数:
5.1W
论文数: 3.0W
被引数: 43
引用论文

引用论文

Elimination of uninformative variables for multivariate calibration
err1996-11-01
err953
PREAI
errCentner, V; Massart, DL; deNoord, OE; deJong, S; Vandeginste, BM; Sterna, C
err分享
err收藏
Evaluation of a new in-clinic method for the detection of canine heartworm antigen
err2011-05-01
err0
PREAI
errAlice C.Y. Lee; Dwight D. Bowman; Araceli Lucio-Forster; Melissa J. Beall; Janice L. Liotta; Ray Dillon
err分享
err收藏
Robust modeling for multivariate calibration transfer by the successive projections algorithm
err2005-03-01
err60
PREAI
errHonorato, FA; Galvao, RKH; Pimentel, MF; Neto, BD; Araújo, MCU; de Carvalho, FR
err分享
err收藏
Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibration
errANALYST
IF3.3
err2003-01-01
err115
PREAI
errBreitkreitz, MC; Raimundo, IM; Rohwedder, JJR; Pasquini, C; Dantas, HA; José, GE; Araújo, MCU
err分享
err收藏
学者 查看更多内容