arrow
返回

The successive projections algorithm for variable selection in spectroscopic multicomponent analysis

delete2001-07-01
delete1.2K
PRE
AI
A
Araújo, MCU *
T
Teresa Cristina Bezerra Saldanha
R
Roberto Kawakami Harrop Galvão
T
Takashi Yoneyama
H
Henrique C. Chame
V
Visani, V
DOI:10.1016/S0169-7439(01)00119-8delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The Successive Projections Algorithm, a forward selection method which uses simple operations in a vector space to minimize variable collinearity, is proposed as a novel variable selection strategy for multivariate calibration. The algorithm was applied to UV-VIS spectrophotometric data for simultaneous analysis of complexes of Co2+ ,Cu2+, Mn2+, Ni2+ e Zn2+ with 4-(2-piridilazo)resorcinol in samples containing the analytes in the 0.02-0.5 mg 1(-1) concentration range. A convenient spectral window was first chosen by a procedure also proposed here and applying Successive Projections Algorithm to this range allowed an improvement of the predictive capabilities of Principal Component Regression, Partial Least Squares and Multiple Linear Regression models using only 20% of the number of wavelengths. Successive Projections Algorithm selection resulted in a root mean square error of prediction at the test set of 0.02 mg l(-1), while the best and worst realizations of a genetic algorithm used for comparison yielded 0.01 and 0.03 mg l(-1). However, genetic algorithm took 200 times longer than Successive Projections Algorithm, and this ratio tends to increase dramatically with the number of wavelengths employed. Finally, unlike genetic algorithm, Successive Projections Algorithm is a deterministic search technique whose results are reproducible and it is more robust with respect to the choice of the validation set. (C) 2001 Elsevier Science B.V. All rights reserved.
Keyword:
successive projections algorithm
variable selection
multicomponent analysis
UV-VIS spectrophotometry
multivariate calibration
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Chemometrics and Intelligent Laboratory Systems 封面图
Chemometrics and Intelligent Laboratory Systems
IF:
3.8
论文数:
4.6K
被引数:
1.2W

机构

暂无机构信息
引用论文

引用论文

Elimination of uninformative variables for multivariate calibration
err1996-11-01
err953
PREAI
errCentner, V; Massart, DL; deNoord, OE; deJong, S; Vandeginste, BM; Sterna, C
err分享
err收藏
Further characterization of the glycan-binding specificity of the seed lectin from vatairea macrocarpa and its dependence of pH
err2000-08-01
err0
PREAI
errMarcio V. Ramos; Liezelotte R. Bomfim; Benildo S. Cavada; Nylane M.N. Alencar; Thalles B. Grangeiro; Henri Debray
err分享
err收藏
err分享
err收藏
The effect of temperature on the 29Si magic angle spinning n.m.r. spectrum of highly siliceous ZSM-5
err1985-01-01
err0
PREAI
errColin A. Fyfe; Gordon J. Kennedy; George T. Kokotailo; James R. Lyerla; William W. Fleming
err分享
err收藏
学者 查看更多内容