arrow
返回

Thin-Volume Image-Type Angular Displacement Measurement Based on Point Light Reflection

delete2024-01-01
delete0
PRE
AI
于
于海 (Hai Yu) *
Q
Qiuhua Wan
Z
Zhicai Zhao
Y
Yongjie Li
DOI:10.1109/TIM.2024.3432128delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Image-type angular displacement measurement technology based on image recognition algorithm is a high-performance displacement measurement technology with high robustness and fault tolerance. In our previous research, using parallel light sources to illuminate the grating disk can achieve high measurement resolution and measurement accuracy. However, due to the optical path height of the transmission displacement measurement, the measurement volume cannot be further reduced in the axial direction. Therefore, a thin-volume image-type displacement measurement (IDM) was proposed here based on point light reflection. First, to reduce the volume of the measuring optical path, a reflective imaging optical path was designed using a point light. Second, to improve robustness of reflective imaging displacement measurements, an absolute encoding method was proposed based on Manchester encoding. Third, based on the encoding pattern used, a decoding and subdivision algorithm was derived. Finally, the resulting method was verified by experimentation. In these experiments, the axial height of the test measuring optical path was only 6 mm. Based on Manchester encoding, the method achieved more than 25-bit measurement resolution and 3.11 error standard deviation when the grating encoder at 86 mm. This research greatly reduced the optical path volume of angular displacement measurements, providing a technical basis for thin-volume and high-performance photoelectric displacement measurement.
Keyword:
Angular displacement measurement
Manchester encoding
metal code disk
point light imaging
Angular displacement measurement
Manchester encoding
metal code disk
point light imaging

期刊

IEEE Transactions on Instrumentation and Measurement 封面图
IEEE Transactions on Instrumentation and Measurement
IF:
5.9
论文数:
2.0W
被引数:
5.8W

机构

C
chinese academy of sciences
学者数:
56.7W
论文数: 45.0W
被引数: 704
引用论文

引用论文

An Effective Method to Improve the Accuracy of a Vernier-Type Absolute Magnetic Encoder
err2021-08-01
err19
PREAI
errTon Hoang Nguyen; Ha Xuan Nguyen; Thuong Ngoc-Cong Tran; Park, Jae Wan; Kien Minh Le; Vinh Quang Nguyen; Jeon, Jae Wook
err分享
err收藏
Longitudinal Competency-Based Point-of-Care Ultrasound Curriculum in Anesthesiology: Description and Initial Experience With PGY1 and PGY2 Trainees
err2020-03-01
err0
PREAI
errMegan M. Rashid; Laura A. Lahaye; Christa L. Riley; Spencer Liebman; William P. Murphy; Pranav R. Shah
err分享
err收藏
High-precision absolute linear encoder based on a standard calibrated scale
err2018-07-01
err31
PREAI
errLashmanov, Oleg U.; Vasilev, Aleksandr S.; Vasileva, Anna V.; Anisimov, Andrei G.; Korotaev, Valery V.
err分享
err收藏
Absolute angle measurement using a phase-encoded binary graduated disk
err2016-02-01
err51
PREAI
errKim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan; Eom, Tae Bong
err分享
err收藏
An anti-spot, high-precision subdivision algorithm for linear CCD based single-track absolute encoder
err2019-04-01
err24
PREAI
errYuan, Pengfei; Huang, Daqing; Lei, Zhongkui; Xu, Cheng
err分享
err收藏
err分享
err收藏
An absolute rotary position sensor based on cylindrical coordinate color space transformation
err2014-07-01
err58
PREAI
errBajic, Jovan S.; Stupar, Dragan Z.; Dakic, Bojan M.; Zivanov, Milos B.; Nagy, Laszlo F.
err分享
err收藏
Ratiometric-Linearization-Based High-Precision Electronic Interpolator for Sinusoidal Optical Encoders
err2018-10-01
err43
PREAI
errYe, Guoyong; Liu, Hongzhong; Wang, Yang; Lei, Biao; Shi, Yongsheng; Yin, Lei; Lu, Bingheng
err分享
err收藏
学者 查看更多内容