arrow
Return

Angular needle tracker and stabilizer for image-guided interventions

delete2020-11-18
delete3
delete
OA
AI
Z
Zhuo Zhao
R
Rui Li
L
Lingwen J. Xu
D
Dieter R. Enzmann
B
Bradford J. Wood
Z
Zion Tsz Ho Tse *
DOI:10.1080/13645706.2020.1832122delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Introduction: Minimally invasive image-guided interventions have changed the face of procedural medicine. For these procedures, safety and efficacy depend on precise needle placement. Needle targeting devices help improve the accuracy of needle placement, but their use has not seen broad penetration. Some of these devices are costly and require major modifications to the clinical workflow. In this article, we developed a low-cost, disposable, and easy-to-use angulation tracking device, which was based on a redesigned commercial passive needle holder. Material and methods: The new design provided real-time angulation information for needle tracking. In this design, two potentiometers were used as angulation sensors, and they were connected to two axes of the passive needle holder's arch structure through a 3 D-printed bridge structure. A control unit included an Arduino Pro Mini, a Bluetooth module, and two rechargeable batteries. The angulation was calculated and communicated in real time to a novel developed smartphone app, where real-time angulation information was displayed for guiding the operator to position the needle to the planned angles. Results: The open-air test results showed that the average errors are 1.03 degrees and 1.08 degrees for left-right angulation and head-foot angulation, respectively. The animal cadaver tests revealed that the novel system had an average angular error of 3.2 degrees and a radial distance error of 3.1 mm. Conclusions: The accuracy was comparable with some commercially available solutions. The novel and low-cost needle tracking device may find a role as part of a real-time precision approach to both planning and implementation of image-guided therapies.
Keywords:
Angulation
smartphone
needle placement
image-guided therapy
medical device
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

M
Minimally Invasive Therapy and Allied Technologies
IF:
2
Papers:
11
Citations:
1.4K

Organization

N
national institutes of health (nih) - usa
Scholars:
10.3W
Papers: 8.2W
Citations: 111
U
university system of georgia
Scholars:
7.3W
Papers: 6.6W
Citations: 101
University of California System cover
University of California System
Scholars:
37.7W
Papers: 33.8W
Citations: 6.6K
U
University of Georgia
Scholars:
661
Papers: 286
Citations: 0
U
University of California Los Angeles
Scholars:
456
Papers: 229
Citations: 0
researcher View more organizations
Cited Papers

Cited Papers

Anesthesia for shared airway surgery in children
err2020-01-20
err0
PREAI
errJames Bradley; Gi Soo Lee; James Peyton
errShare
errSave
Nonholonomic modeling of needle steering
err2006-05-01
err510
PREAI
errWebster, Robert J., III; Kim, Jin Seob; Cowan, Noah J.; Chirikjian, Gregory S.; Okamura, Allison M.
errShare
errSave
Viral Inhibition of Bacterial Phagocytosis by Human Macrophages: Redundant Role of CD36
err2016-10-04
err0
errOAAI
errGrace E. Cooper; Zoe C. Pounce; Joshua C. Wallington; Leidy Y. Bastidas-Legarda; Ben Nicholas; Chiamaka Chidomere; Emily C. Robinson; Kirstin Martin; Anna S. Tocheva; Myron Christodoulides; Ratko Djukanovic; Tom M. A. Wilkinson; Karl J. Staples
errShare
errSave
Streptococcus pneumoniae Enhances Human Respiratory Syncytial Virus Infection In Vitro and In Vivo
err2015-05-13
err0
errOAAI
errD. Tien Nguyen; Rogier Louwen; Karin Elberse; Geert van Amerongen; Selma Yüksel; Ad Luijendijk; Albert D. M. E. Osterhaus; W. Paul Duprex; Rik L. de Swart
errShare
errSave
Stereotactic Image-Guided Microwave Ablation for Malignant Liver Tumors-A Multivariable Accuracy and Efficacy Analysis
err2020-06-10
err31
errOAAI
errTinguely, Pascale; Frehner, Lorenz; Lachenmayer, Anja; Banz, Vanessa; Weber, Stefan; Candinas, Daniel; Maurer, Martin H.
errShare
errSave
Usefulness of surgical lung biopsies after cryobiopsies when pathological results are inconclusive or show a pattern suggestive of a nonspecific interstitial pneumonia
err2020-09-04
err0
errOAAI
errBenjamin Bondue; Dimitri Leduc; Antoine Froidure; Thierry Pieters; Olivier Taton; Vincent Heinen; Patrick Alexander; Delphine Hoton; Florence Dome; Myriam Remmelink
errShare
errSave
Standardized assessment of new electromagnetic field generators in an interventional radiology setting
err2012-05-25
err65
PREAI
errMaier-Hein, L.; Franz, A. M.; Birkfellner, W.; Hummel, J.; Gergel, I.; Wegner, I.; Meinzer, H. -P.
errShare
errSave
Method for rapid MRI needle tracking
err2004-04-26
err12
errOAAI
errKochavi, E; Goldsher, D; Azhari, H
errShare
errSave
researcher View more