arrow
Return

Data-driven alarm parameter optimization

delete2025-05-01
delete0
PRE
AI
T
Tayfun Eylen *
P
P. Erhan Eren
A
Altan Koçyiğit
DOI:10.1016/j.compchemeng.2025.109041delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Most manufacturing sector businesses utilize advanced control mechanisms to sustain their ongoing operations. An alarm management system is one of these control mechanisms that works as a safety barrier, and it contains alarm messages indicating abnormal situations to operators. The causes of alarms mainly result in a harmful state of operations that should be eliminated as quickly as possible to minimize possible negative results. However, the size of the system, lack of people directing the system, and process-dependent peak conditions may lead operators to miss some critical alarms. Quality and quantity of products, job safety, and operational costs are some of the features negatively affected by these missing alarms. The proposed work aims to combine a well-established alarm management philosophy with advanced data analytics techniques to optimize decision variables in alarm management processes. This study introduces a novel data-driven optimization method that leverages the Tennessee Eastman Process as a benchmark to validate its effectiveness. The proposed method aims to ensure continuous alarm system health by contributing to the automation of the parameter optimization process in the life cycles of alarm management systems. Key contributions include the development of a method to associate disturbances with alarms, the creation of an alarm simulation platform, and the improvement of alarm parameters through a unique optimization approach. The results show that there is a trade-off between alarm reaction delay, which refers to the time between disturbances and the first relevant alarm and number of alarms and alarm on times. This trade-off can be evaluated in the desired direction by taking into account the priorities of the process.
Keywords:
Alarm management
Process safety
Alarm parameter optimization
Alarm KPI's
Tennessee Eastman Process

Journal

C
Computers and Chemical Engineering
IF:
3.9
Papers:
8.1K
Citations:
1.7W

Organization

M
Middle East Technical University
Scholars:
7.4K
Papers: 6.7K
Citations: 6.3K
Cited Papers

Cited Papers

Alarm rationalization and dynamic risk analyses for rare abnormal events
err2024-05-01
err4
PREAI
errSudarshan, Vikram; Seider, Warren D.; Patel, Amish J.; Oktem, Ulku G.; Arbogast, Jeffrey E.
errShare
errSave
Characterization of polymer matrix and low melting point solder for anisotropic conductive film
err2008-02-01
err0
PREAI
errYong-Sung Eom; Ji-Won Baek; Jong-Tae Moon; Jae-Do Nam; Jong-Min Kim
errShare
errSave
Sequence Mining Based Alarm Suppression
err2018-01-01
err22
errOAAI
errDorgo, Gyula; Bonyi, Janosa
errShare
errSave
Understanding rare safety and reliability events using forward-flux sampling
err2021-10-01
err6
PREAI
errSudarshan, Vikram; Seider, Warren D.; Patel, Amish J.; Arbogast, Jeffery E.
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Enhancing Alarm Prioritization in the Alarm Management Lifecycle
err2022-01-01
err4
errOAAI
errParsa, Kourosh; Hassall, Maureen; Naderpour, Mohsen
errShare
errSave
researcher View more