This paper introduces a new type of miniature device to insert an intrafascicular electrode into a peripheral nervous system that is covered with tough tissue membranes. The developed device is called nerve electrode insertion tool (NEIT) and consists of a nerve holder unit and an electrode insertion unit. Users can easily adjust the insertion position and direction of nerve electrodes while freely manipulating this compact handheld device. This paper introduces the form, configuration, and underlying mechanisms of the device and related surgical procedure. Utility tests using elastomer-made nerve models show that the electrode insertion time and position accuracy, respectively, improve from 72.1 to 4.17 s and 0.37 to 0.11 mm when employing the NEIT. Animal experiment results show that multishank planar electrodes (2 x 2 mm(2)) are successfully implanted into sciatic nerves of six rats. Treadmill tests and histological analysis present the neural functions of all the treated nerves are successfully recovered after three weeks. We expect the NEIT to be employed for other kinds of nerve electrodes and simplify the surgical process in neural engineering research.
Keywords:
Biomedical electrodes
micro electrodes
neural engineering
surgical instruments
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

I
IEEE-ASME Transactions on Mechatronics
IF:
7.3
Papers:
5.4K
Citations:
2.4W

Organization

S
sungkyunkwan university (skku)
Scholars:
3.7W
Papers: 3.6W
Citations: 49
K
korea institute of science & technology (kist)
Scholars:
1.2W
Papers: 1.3W
Citations: 23
Cited Papers

Cited Papers

errShare
errSave
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
err2010-09-01
err403
PREAI
errBoretius, Tim; Badia, Jordi; Pascual-Font, Aran; Schuettler, Martin; Navarro, Xavier; Yoshida, Ken; Stieglitz, Thomas
errShare
errSave
A neural interface provides long-term stable natural touch perception
err2014-10-08
err654
errOAAI
errTan, Daniel W.; Schiefer, Matthew A.; Keith, Michael W.; Anderson, James Robert; Tyler, Joyce; Tyler, Dustin J.
errShare
errSave
Caries clinical trial of a remineralising toothpaste in radiation patients
err2008-05-14
err0
PREAI
errAthena Papas; David Russell; Mabi Singh; Ralph Kent; Cal Triol; Anthony Winston
errShare
errSave
Lenalidomide-induced diarrhea in patients with myeloma is caused by bile acid malabsorption that responds to treatment
err2014-10-09
err0
errOAAI
errCharlotte Pawlyn; Mohid S. Khan; Ann Muls; Priya Sriskandarajah; Martin F. Kaiser; Faith E. Davies; Gareth J. Morgan; H. Jervoise N. Andreyev
errShare
errSave
A review on natural background radiation
err2013-01-01
err0
errOAAI
errDaryoush Shahbazi-Gahrouei; Mehrdad Gholami; Samaneh Setayandeh
errShare
errSave
researcher View more