Abstract

Abstract

En 中文
Although the use of comprehensive two-dimensional liquid chromatography (LC x LC) as a powerful separation technique is continuously increasing, its employment in quantification experiments is rather limited. The present research is focused on the quantification of a series of standards, as well as real-world sample compounds, by using dedicated laboratory-constructed LC x LC software, developed through a novel approach. Moreover, the difficulties encountered during software operation, in various elution conditions, are described and discussed. The results attained were compared with those observed in conventional LC, and no statistically significant differences were observed in the determination of aurapten in grapefruit oil. However, a loss in sensitivity was observed when using LCxLC (limit of detection = 0.10 ppm) compared to conventional LC (limit of detection = 0.05 ppm) as a consequence of the sample dilution in comprehensive two-dimensional liquid chromatography.
Keywords:
NORMAL-PHASE
GAS-CHROMATOGRAPHY
MASS-SPECTROMETRY
SEPARATION
RESOLUTION
TOOL
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Analytical Chemistry cover
Analytical Chemistry
IF:
6.7
Papers:
4.7W
Citations:
15.9W

Organization

D
dow chemical company
Scholars:
2.6K
Papers: 1.6K
Citations: 0
U
University of Messina
Scholars:
1.5W
Papers: 1.1W
Citations: 1.1W
Cited Papers

Cited Papers

Elucidation of carotenoid patterns in citrus products by means of comprehensive normal-phase x reversed-phase liquid chromatography
err2006-10-19
err99
PREAI
errDugo, Paola; Skerikova, Veronika; Kumm, Tiina; Trozzi, Alessandra; Jandera, Pavel; Mondello, Luigi
errShare
errSave
errShare
errSave
Nitinol Stents With Polymer-Free Paclitaxel Coating for Lesions in the Superficial Femoral and Popliteal Arteries Above the Knee:Twelve-Month Safety and Effectiveness Results From the Zilver PTX Single-Arm Clinical Study
err2011-10-01
err0
PREAI
errMichael D. Dake; Dierk Scheinert; Gunnar Tepe; Jörg Tessarek; Fabrizio Fanelli; Marc Bosiers; Christof Ruhlmann; Zaza Kavteladze; Aaron E. Lottes; Anthony O. Ragheb; Thomas Zeller
errShare
errSave
Comprehensive two-dimensional normal-phase (adsorption) - Reversed-phase liquid chromatography
err2004-03-27
err168
PREAI
errDugo, P; Favoino, O; Luppino, R; Dugo, G; Mondello, L
errShare
errSave
researcher View more