arrow
Return

Visually Navigated Bronchoscopy using three cycle-Consistent generative adversarial network for depth estimation

delete2021-10-01
delete26
delete
OA
AI
A
Artur Banach *
F
Franklin King
F
Fumitaro Masaki
H
Hisashi Tsukada
N
Nobuhiko Hata
DOI:10.1016/j.media.2021.102164delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
[Background] Electromagnetically Navigated Bronchoscopy (ENB) is currently the state-of-the art diagnostic and interventional bronchoscopy. CT-to-body divergence is a critical hurdle in ENB, causing navigation error and ultimately limiting the clinical efficacy of diagnosis and treatment. In this study, Visually Navigated Bronchoscopy (VNB) is proposed to address the aforementioned issue of CT-to-body divergence. [Materials and Methods] We extended and validated an unsupervised learning method to generate a depth map directly from bronchoscopic images using a Three Cycle-Consistent Generative Adversarial Network (3cGAN) and registering the depth map to preprocedural CTs. We tested the working hypothesis that the proposed VNB can be integrated to the navigated bronchoscopic system based on 3D Slicer, and accurately register bronchoscopic images to pre-procedural CTs to navigate transbronchial biopsies. The quantitative metrics to asses the hypothesis we set was Absolute Tracking Error (ATE) of the tracking and the Target Registration Error (TRE) of the total navigation system. We validated our method on phantoms produced from the pre-procedural CTs of five patients who underwent ENB and on two ex-vivo pig lung specimens. [Results] The ATE using 3cGAN was 6.2 +/-2.9 [mm]. The ATE of 3cGAN was statistically significantly lower than that of cGAN, particularly in the trachea and lobar bronchus (p < 0.001). The TRE of the proposed method had a range of 11.7 to 40.5 [mm]. The TRE computed by 3cGAN was statistically significantly smaller than those computed by cGAN in two of the five cases enrolled (p < 0.05). [Conclusion] VNB, using 3cGAN to generate the depth maps was technically and clinically feasible. While the accuracy of tracking by cGAN was acceptable, the TRE warrants further investigation and improvement. (c) 2021 Elsevier B.V. All rights reserved.
Keywords:
Bronchoscopy
Image-guided surgery
Lung cancer
CT Imaging

Journal

Medical Image Analysis cover
Medical Image Analysis
IF:
11.8
Papers:
3.8K
Citations:
2.4W

Organization

H
Harvard University
Scholars:
26.5W
Papers: 22.0W
Citations: 28.7W
Cited Papers

Cited Papers

Prediction of retail product weight and percentage using ultrasound and carcass measurements in beef cattle
err2003-07-01
err0
PREAI
errS. P. Greiner; G. H. Rouse; D. E. Wilson; L. V. Cundiff; T. L. Wheeler
errShare
errSave
Cancer statistics, 2019
err2019-01-08
err5.5K
errOAAI
errSiegel, Rebecca L.; Miller, Kimberly D.; Jemal, Ahmedin
errShare
errSave
Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images
err2002-09-01
err125
PREAI
errMori, K; Deguchi, D; Sugiyama, J; Suenaga, Y; Toriwaki, J; Maurer, CR; Takabatake, H; Natori, H
errShare
errSave
Meta-analysis of Guided Bronchoscopy for the Evaluation of the Pulmonary Nodule
errCHEST
IF8.6
err2012-08-01
err513
errOAAI
errMemoli, Jessica S. Wang; Nietert, Paul J.; Silvestri, Gerard A.
errShare
errSave
3D MDCT-based system for planning peripheral bronchoscopic procedures
err2009-03-01
err47
errOAAI
errGibbs, Jason D.; Graham, Michael W.; Higgins, William E.
errShare
errSave
errShare
errSave
researcher View more