A handheld real time thermal cycler for bacterial pathogen detection

delete2003-08-01
delete135
PRE
AI
H
Higgins, JA *
S
Shanavaz Nasarabadi
J
Jeffrey S. Karns
S
Shelton, DR
M
Mary Cooper
A
Aiah A Gbakima
R
R.P. Koopman
DOI:10.1016/S0956-5663(02)00252-Xdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The handheld advanced nucleic acid analyzer (HANAA) is a portable real time thermal cycler unit that weighs under I kg and uses silicon and platinum-based thermalcycler units to conduct rapid heating and cooling of plastic reaction tubes. Two light emitting diodes (LED) provide greater than 1 mW of electrical power at wavelengths of 490 nm (blue) and 525 nm (green), allowing detection of the dyes FAM and JOE/TAMRA. Results are displayed in real time as bar graphs, and up to three, 4-sample assays can be run on the charge of the 12 V portable battery pack. The HANAA was evaluated for detection of defined Escherichia coli strains, and wild-type colonies isolated from stream water, using PCR for the lac Z and Tir genes. PCR reactions using SYBR Green dye allowed detection of E. coli ATCC 11775 and E coli O157:H7 cells in under 30 min of assay time; however, background fluorescence associated with dye binding to nonspecific PCR products was present. DNA extracted from three isolates of Bacillus anthracis Ames, linked to a bioterrorism incident in Washington DC in October 2001, were also successfully tested on the HANAA using primers for the vrrA and capA genes. Positive results were observed at 32 and 22 min of assay time, respectively. A TaqMan probe specific to the aroQ gene of Erwinia herbicola was tested on the HANAA and when 500 cells were used as template, positive results were observed after only 7 min of assay time. Background fluorescence associated with the use of the probe was negligible. The HANAA is unique in offering real time PCR in a handheld format suitable for field use; a commercial version of the instrument, offering six reaction chambers, is available as of Fall 2002. (C) 2002 Elsevier Science B.V. All rights reserved.
Keyword:
TaqMan
PCR
detection
Escherchia coli O157 : H7
Bacillus anthracis
Erwinia herbicola
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Biosensors and Bioelectronics 封面图
Biosensors and Bioelectronics
IF:
10.5
论文数:
1.8W
被引数:
7.7W

机构

暂无机构信息
引用论文

引用论文

Brillouin study of liquid and solid ammonia up to 20 GPa
err1988-10-01
err0
PREAI
errM. Gauthier; Ph. Pruzan; J.C. Chervin; A. Polian
err分享
err收藏
Epigenetic modification of the human CCR6 gene is associated with stable CCR6 expression in T cells
err2011-03-10
err0
errOAAI
errSvenja Steinfelder; Stefan Floess; Dirk Engelbert; Barbara Haeringer; Udo Baron; Laura Rivino; Bodo Steckel; Andreas Gruetzkau; Sven Olek; Jens Geginat; Jochen Huehn; Alf Hamann
err分享
err收藏
Extrasolar planets
err2008-01-02
err0
PREAI
errDimitar D. Sasselov
err分享
err收藏
Real-time microchip PCR for detecting single-base differences in viral and human DNA
err1998-03-25
err202
PREAI
errIbrahim, MS; Lofts, RS; Jahrling, PB; Henchal, EA; Weedn, VW; Northrup, MA; Belgrader, P
err分享
err收藏
err分享
err收藏
Detection of PCR products using self-probing amplicons and fluorescence
err1999-08-01
err904
PREAI
errWhitcombe, D; Theaker, J; Guy, SP; Brown, T; Little, S
err分享
err收藏
Handheld advanced nucleic acid analyzer手持式高级核酸分析仪
err2000-12-29
err3
PREAI
errBenett, WJ; Richards, JB; Stratton, P; Hadley, DR; Bodtker, BH; Nasarabadi, SL; Milanovich, FP; Mariella, RP; Koopman, RP; Belgrader, P
err分享
err收藏
A battery-powered notebook thermal cycler for rapid multiplex real time PCR analysis
err2000-12-06
err154
PREAI
errBelgrader, P; Young, S; Yuan, B; Primeau, M; Christel, LA; Pourahmadi, F; Northrup, MA
err分享
err收藏
Miniaturized detection system for handheld PCR assays
err2000-12-29
err0
PREAI
errRichards, JB; Benett, WJ; Stratton, PL; Hadley, DR; Nasarabadi, SL; Milanovich, FP
err分享
err收藏
学者 查看更多内容