Fluoroscopy-Free Tip Shape Estimation for Flexible Endoscope Using Permanent Magnet Positioning

delete2024-01-01
delete0
PRE
AI
B
Bowen Lv
秦岩丁 封面图
秦岩丁 (Yanding Qin) *
Y
Yueyang Shi
H
Houde Dai
韩建达 封面图
韩建达 (Jianda Han)
DOI:10.1109/TIM.2024.3476592delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Flexible endoscopes can reach the lesion via a small incision or the patient's natural orifices, exhibiting minimally invasive or noninvasive diagnosis and surgery capabilities. Precise position and shape estimations of the soft tip are key to guarantee the precision of operation. Different from conventional fluoroscopy-based measurements, this article proposes a tip shape estimation method for flexible endoscopes based on permanent magnet positioning. A tip shape-sensing probe with embedded magnets is designed to be inserted into the working channel of the flexible endoscope, serving as positioning markers. Subsequently, the tip shape of the flexible endoscope is estimated using non-uniform rational B-spline (NURBS) curve approximation by optimizing the control points and weights via the path points, tangent lines, and tip length. Further, tip shape estimation experiments are conducted on a flexible ureteroscope and an upper gastrointestinal endoscope with the help of a G-arm surgical X-ray fluoroscopy system and computed tomography (CT) scanner, respectively. The mean contour error is measured to 0.6-1.3 mm for different bending angles. Experimental results demonstrate that the proposed method achieves a good estimation performance, thus showing great potential for fluoroscopy-free measurement and navigation in flexible endoscopic surgeries.
Keyword:
Shape
Estimation
Endoscopes
Splines (mathematics)
Magnetometers
Surface topography
Surface reconstruction
Permanent magnets
Surgery
Shape measurement
Constrained optimization
flexible endoscope
non-uniform rational B-spline (NURBS) curve
permanent magnet positioning
shape estimation

期刊

IEEE Transactions on Instrumentation and Measurement 封面图
IEEE Transactions on Instrumentation and Measurement
IF:
5.9
论文数:
2.0W
被引数:
5.8W

机构

N
nankai university
学者数:
4.8W
论文数: 3.3W
被引数: 74
引用论文

引用论文

err分享
err收藏
err分享
err收藏
Morphology and Tension Perception of Cable-Driven Continuum Robots
err2023-02-01
err32
PREAI
errLiu, Zhongzhen; Cai, Zhiqin; Peng, Haijun; Zhang, Xingang; Wu, Zhigang
err分享
err收藏
The SHURUI System: A Modular Continuum Surgical Robotic Platform for Multiport, Hybrid-Port, and Single-Port Procedures
err2022-10-01
err29
PREAI
errChen, Yuyang; Zhang, Chao; Wu, Zhonghao; Zhao, Jiangran; Yang, Bo; Huang, Jia; Luo, Qingquan; Wang, Linhui; Xu, Kai
err分享
err收藏
Flexible Robot With Variable Stiffness in Transoral Surgery
err2020-02-01
err67
PREAI
errLi, Changsheng; Gu, Xiaoyi; Xiao, Xiao; Lim, Chwee Ming; Ren, Hongliang
err分享
err收藏
Electrophysiology Catheter Detection and Reconstruction From Two Views in Fluoroscopic Images
err2016-02-01
err35
PREAI
errHoffmann, Matthias; Brost, Alexander; Koch, Martin; Bourier, Felix; Maier, Andreas; Kurzidim, Klaus; Strobel, Norbert; Hornegger, Joachim
err分享
err收藏
学者 查看更多内容