Abstract

Abstract

En 中文
In MRI-guided breast intervention, the biopsy procedure is carried out by manually inserting a biopsy gun. However, some lesions are barely accessible with conventional tools, and the imaging process must be repeated multiple times for a better insertion coordinate. In this paper, we present a parallel robot for MRI-guided breast intervention. The robot employs a nonmagnetic, compact design, and has a unique three-link-four-rotational (3-4R) parallel mechanism that can insert the biopsy gun from various angles. The robot is remotely driven by a cable-actuated system and piezo-electric motors. It can be safely operated inside MRI bores with promising biopsy needle targeting accuracy. Comparative experiments are performed to validate the kinematics and to evaluate the performance on repetitive accuracy, structural stiffness, cable tension, and magnetic resonance. The experimental results show that the robot satisfies the operational requirements and can provide effective assistance in clinical breast biopsy.
Keywords:
Breast biopsy
mechanism design
medical robotics
MRI robotics
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

I
IEEE Transactions on Medical Robotics and Bionics
IF:
3.8
Papers:
847
Citations:
1.8K

Organization

C
china agricultural university
Scholars:
5.1W
Papers: 3.0W
Citations: 43
C
Chinese University of Hong Kong
Scholars:
3.4W
Papers: 3.2W
Citations: 5.6W
Cited Papers

Cited Papers

Transmission of small ruminant lentiviruses
err2004-07-01
err0
PREAI
errB.A Blacklaws; E Berriatua; S Torsteinsdottir; N.J Watt; D de Andres; D Klein; G.D Harkiss
errShare
errSave
MRI-Guided Vacuum-Assisted Breast Biopsy: A Phantom and Patient Evaluation of Targeting Accuracy
err2009-07-23
err18
errOAAI
errEl Khouli, Riham H.; Macura, Katarzyna J.; Barker, Peter B.; Elkady, Laila M.; Jacobs, Michael A.; Vogel-Claussen, Jens; Bluemke, David A.
errShare
errSave
Evaluation of rhBMP-2 With an OPLA Carrier in a Canine Posterolateral (Transverse Process) Spinal Fusion Model
err1995-12-01
err0
errOAAI
errHarvinder S. Sandhu; Linda E. A. Kanim; J. Michael Kabo; Jeffrey M. Toth; Erik N. Zeegen; David Liu; Leanne L. Seeger; Edgar G. Dawson
errShare
errSave
Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy
err2015-08-01
err105
errOAAI
errSu, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.
errShare
errSave
Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention
err2013-02-01
err96
errOAAI
errKrieger, Axel; Song, Sang-Eun; Cho, Nathan Bongjoon; Iordachita, Iulian I.; Guion, Peter; Fichtinger, Gabor; Whitcomb, Louis L.
errShare
errSave
Single-mode Nd/sup 3+/-doped graded-index polymer waveguide amplifier
err1993-11-01
err0
PREAI
errR.T. Chen; M. Lee; S. Natarajan; Chuan Lin; Z.Z. Ho; D. Robinson
errShare
errSave
researcher View more